Mounting/Physical Installation
Figure 7 Mounting Hole Dimensions
2.2.1 Mounting Hole Pattern
The Nova-65 SC unit is mounted on a 465-mm bolt circle pattern as shown in
Fig. 8. Optional mounting hardware consists of 4 S/S bolts (2” x 5”), 8 flat
washers and 4 self-locking hex nuts.
2.2.2 Installation
Mount the unit with bolt circle as described in the previous step. Turn the
On/Off Winter Charging switch to the
On
(Operation) position. Please note
that this switch is a high quality, totally sealed switch with pull-to-unlock
toggle level to prevent accidental toggle movement. It is placed in the Off
position for shipping or storage. The Winter Charging position is for charging
the battery without operating the light to help accelerate the charging of the
battery either before field installation or during long-term storage.
Note
: for
Winter charging the lantern must be left outdoors, exposed to sunlight.
The On/Off/Winter Charging Switch is located behind the cover plate as
shown in Fig. 8. Once the switch is accessed, pull the switch toggle forward,
releasing the locking mechanism, and move up for On/Operate position,
down for Winter Charging position, or leave the switch in the middle position
for shipping or storage of the lantern.