PRO-SPOTTER
AIR SYSTEM
TICO Manufacturing
Service Manual
8-3
Pressure Buildup, Low-Pressure
Warning Cutoff, and Governor Cutout
Test
1.
Open reservoir drain valves and drain system.
2.
Start engine and run at fast idle. Low-pressure
warning should be active.
3.
Begin timing pressure buildup when system pressure
reaches 345 kPa/3.45 bar (50 psi). Record the
following data;
— The pressure at which low-pressure warning cuts
off.
— The time at which system pressure has reached
621kPa/6.21 bar (90 psi). Elapsed time should
not exceed specification.
—
4.
Continue observing gauge. The governor cutout
should limit system air pressure to specification.
AIR DRYER
Removal
1.
Park and prepare tractor for service. (See “Park
Tractor Safely” on page 1-3.)
CAUTION
2.
Release air system pressure. (See “RELIEVING AIR
SYSTEM PRESSURE” on page 8-6.)
Figure 8-1: Air Dryer
3.
Disconnect air lines (1—3). Close all openings using
caps and plugs.
4.
Install identification tags and disconnect electrical
connector (4).
5.
Remove band (5).
6.
Remove cap screws (6), washers (7), lock nuts (8),
and air dryer (9).
7.
Repair or replace components as necessary.
Specification
Low-Pressure Warning Cutoff
414 kPa
4.1 bar
60 psi
System Pressure Buildup (time)
5 min
Specification
Maximum System Pressure
896 kPa
9.0 bar
130 psi
Governor Cutout Pressure
827 kPa
8.3 bar
120 psi
• Avoid personal injury from explosion. Air
system components may contain pressurized
gases. Exposure to excessive heat may
cause components to explode.
• Avoid personal injury from high-pressure
gases or debris. High-pressure release of
gases or debris from a pressurized system
can cause penetrating injuries. Relieve
system pressure from air system before
servicing.
1
Supply Air Line
6
Cap Screw (2 used)
2
Control Air Line
7
Washer (4 used)
3
Discharge Air Line
8
Lock Nut (2 used)
4
Electrical Connector
9
Air Dryer
5
Band
2
TPS-087
1
3
4
5
9
6
7
8
Содержание Pro-Spotter
Страница 1: ...TICO Manufacturing Service Manual 4 4 37 6 TICO Manufacturing 1 30 2018 130 41055 3...
Страница 2: ...Pro Spotter Service Manual TICO Manufacturing...
Страница 12: ...0 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 28: ...1 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 44: ...2 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 56: ...3 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 68: ...4 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 92: ...6 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 114: ...8 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 122: ...9 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 130: ...10 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 134: ...11 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 144: ...12 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 154: ...13 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 184: ...15 0 Service Manual TICO Manufacturing PRO SPOTTER...
Страница 204: ...IDX 0 Service Manual TICO Manufacturing PRO SPOTTER...