![TIC AVP100 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/tic/avp100/avp100_instruction-manual_1114202005.webp)
07
08
Option 1: Single 100v output
Option 2: Single 70v output
Option 3: 4-16Ω output
Zone 1 terminals
Zone 2 terminals
Zone 3 terminals
Zone 4 terminals
AVP100 can be set up in one of four options. Utilizing multiple options simutaneously may
cause issues and damage to the amplifier. Please ensure the polarity of speaker wires are
correctly matched and connected.
Note:
1. Please make sure that the power is turned off during speaker installation. When the power is on,
there may be a risk of electric shock.
2. Please ensure the sum of the power and impedance load of the speakers connected does not
exceed the specified range of the amplifier. Ideally, the total power load doesn't exceed 80% of the
rated output power of the amplifier.
Operation:
Option 4: 4-zone 70v output (can be used in any combination of the 4 zones)