Tian kan Electronic WS1040 Скачать руководство пользователя страница 5

sensor, if in three minutes no signal receiving then search fails, once receive singal the unit will only work
with the sensor establishing a data link, 48 seconds of cycle synchronization to receive the sensor data,
so in order to ensure that machine can work, be sure to install outdoor sensor fistly, then mount the

receiver battery, icon

in the search process will remain flashing until search the outdoor sensor or

search fails, the search process, please do not carry out any operation of this machine;

. Automatic Calibration time: by receiving radio control clock signal (RCC) to achieve the automatic

Calibration time function, the unit will in 2:00:00 and 12:00:00 in the daily timing receiving radio

controlled clock signal, in receiving procession

icon will remain flashing until the completion of

reception at the receiver, please do not carry out any operation of this machine. If you receive

successfully, then Display

icon, otherwise the

icon will disappear, the longest time to receive

is 8 minutes.

. Data storage: user via USB cable connect to the PC, the

icon is displayed, indicating that the

USB is ready, users can query maximum/minimum on the computer, setting the alarm value, set all
corresponding kinds of parameters, the user via the computer in 5 minutes to 240 minutes to set up data
logging cycle, you can save up to two years of meteorological data, users can also download
meteorological data to the computer to save.

Keys operation

The Machine has MODE, NEXT, SET, INC/+, DEC/- five buttons, In addition to normal mode, time

mode, date mode, wind speed mode, memory historical data mode, rainfall patterns, indoor temperature
patterns. Indoor humidity mode, outdoor temperature mode, outdoor humidity mode, weather forecast
patterns, Air pressure mode, pressure histogram mode, in any operating mode, short press MODE
button to enter next work mode, short press NEXT button to enter next work item, if pressing key it is
alarming, or outdoor sensor data is being received or is receiving the wireless control clock signal, then
pressing key just close the corresponding function and will not implement the key functions. the detailed
operation of the various operating modes are described as follows:

2. Clock Mode

In normal mode, press MODE button to enter time mode, the user can carry out time-related settings in
this mode, press the NEXT button to enter the next item:

(1) Time zone setting:
Users according to their geographical location to adjust time zone settings, short press INC/+ button
to increase the value of the time zone setting, short press the DEC/- button to decrease the time
zone setting, press and hold INC/+ button more than 3seconds can quickly increase the time zone
setting values

​​

, press and hold the DEC/- buttons more than 3 seconds can quickly decrease the

time zone setting value;
(2) Hour display format setting:
User can adjust hour display format for 12 hours or 24 hours, short press INC/+ or DEC/- buttons to
switch;
(3) Daylight Saving Time setting:

Содержание WS1040

Страница 1: ...WS1040 User Manual Professioanl Wireless Weather Station with solar Power PC Link ...

Страница 2: ... 6 Rainfall Mode 6 7 Indoor Temperature Mode 6 8 Indoor Humidity Mode 7 9 Outdoor Temperature Mode 8 10 Outdoor Humidity Mode 8 11 Weather Forecast Mode 9 12 Barometric Pressure Mode 9 13 Pressure Histogram Mode 10 14 Smart Weather software 11 Specification 13 1 Receiver 13 2 Outdoor transmitter 14 3 Setting Up Guide 14 ...

Страница 3: ... alarm value can be set independently you can query the maximum temperature value and the minimum temperature values user setting 9 Wind speed user can set average wind speed or gust wind speed the wind speed high alarm value can be set independently you can query the corresponding maximum value the display unit can be set to m s km h mph knots or bft 10 Rainfall the user can set as time period sh...

Страница 4: ... control clock signal standard location of the transmitting station in Colorado the transmit power is 50 kilowatts it can cover most areas of America within the range of 2000 km 3 MSF is Britain wireless control clock signal standard location of the transmitting station in middle of Britain the transmit power is 17 kilowatts it can cover Britain within the range of 1000 km also part of western Eur...

Страница 5: ...lso download meteorological data to the computer to save Keys operation The Machine has MODE NEXT SET INC DEC five buttons In addition to normal mode time mode date mode wind speed mode memory historical data mode rainfall patterns indoor temperature patterns Indoor humidity mode outdoor temperature mode outdoor humidity mode weather forecast patterns Air pressure mode pressure histogram mode in a...

Страница 6: ...crease hours set press and hold INC button over 3 seconds you can quickly increase the hour setting press and hold the DEC button more than 3 seconds can quickly decrease the hours set 7 Alarm clock minutes setting User to adjust the minutes setting of the alarm clock in this mode short press SET button to enable or disable the alarm clock short press INC button to increase the minutes setting pre...

Страница 7: ...ton can switch between average and gust wind speed 2 Wind speed unit setting Users can adjust wind speed unit setting in this mode press INC increase wind speed unit value press DEC button decrease wind speed unit value instruction as follows INC INC INC INC INC m s km h mph knots beaufort DEC DEC DEC DEC DEC m s beaufort knots mph km h 3 High wind speed alarm setting Users can adjust the high win...

Страница 8: ...ainfall display setting Users can adjust the rainfall display setting in this mode short press the INC button to increase rainfall display settings press DEC button to decrease rainfall display settings instruction as follow INC INC INC INC INC 1h 24h week month total DEC DEC DEC DEC DEC 1h total month week 24h 2 Rainfall unit setting Users can adjust rainfall unit in this mode press the INC or DE...

Страница 9: ...larm value press and hold the DEC button more than 3 seconds you can quickly decrease low indoor temperature alarm values 4 Maximum indoor temperature display In this mode user can view the maximum indoor temperature and time records press and hold the SET button over 3 seconds to clear the maximum record 5 Minimum indoor temperature display In this mode user can view the minimum indoor temperatur...

Страница 10: ...DEC buttons to switch between and 3 High outdoor temperature alarm setting In this mode user can adjust the high outdoor temperature alarm setting press SET button to allow or prohibit the high outdoor temperature alarm press the INC button to increase the high outdoor temperature alarm values short press the DEC button to reduce high outdoor temperature alarm value press and hold INC button over ...

Страница 11: ... button over 3 seconds you can quickly increase the Low outdoor humidity alarm value press and hold the DEC button more than 3 seconds you can quickly reduce the Low outdoor humidity alarm values 3 Maximum Outdoor humidity display In this mode user can view maximum outdoor humidity and time records press and hold the SET button over 3 seconds to clear the maximum record 4 Minimum Outdoor humidity ...

Страница 12: ...se the relative pressure press the DEC button to decrease the relative pressure press and hold INC button over 3 seconds you can quickly increase the relative pressure press and hold the DEC buttons more than 3 seconds you can quickly decrease the relative air pressure 4 High air pressure alarm setting In this mode adjust high air pressure alarm settings press SET button to allow or prohibit high ...

Страница 13: ... of green software users just need to copy it to your PC double click the package SmartWeather exe file can start SmartWeather software SmartWeather software starts as follows If base station connect failure through USB cable to your computer then right corner display if connecting successfully you can hear computer issued a drip sound and right corner display indicating communication successfully...

Страница 14: ...the download time of historical data and number of records historical data downloading as following Click the icon of user can enter the restore default parameters confirmation screen as shown below ...

Страница 15: ... completed receiver will remove previous history data Specification 1 Receiver 1 Temperature range 0 50 32 122 Temperature accuracy 1 Temperature resolution 0 1 2 Humidity range 20 99 Humidity accuracy 5 Humidity resolution 1 condition temperature 25 humidity 50 3 Pressure range 920 1080hPa Pressure accuracy 5hPa Pressure resolution 0 1 hPa 4 Transmission data update 48s 5 Alarm 2 minutes 6 Power ...

Страница 16: ... 1 5V AA battery 7 Battery life about 24months 8 Low battery check power on check 00 00 check evey day 9 Work temperature 40 60 104 140 10 Anti rainy Setting Up Guide 1 Insert the stainless steel pipe into the base press a M3 screw nut into the nut slot and then establish them with a PM3 0 25mm screw 2 Insert the transmitter holder into the stainless steel pipe establish them with a PM3 0 22mm scr...

Страница 17: ...ble batteries then cover the battery door Insert the whole transmitter onto the long side of the transmitter holder and establish them with a PM3 0 18mm screw At last insert the wind speed wire RJ45 into the WIND 623K hole of the transmitter 7 Put the rain gauge wire across the waterproof tower case and then insert the RJ45 into the 623K hole of the solar component Put the solar wire across the wa...

Страница 18: ...sted and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...