402.435.4249 www.THUNDERSTONEMFG.com Page 3
Control Box Operation, Wireless Operation
1.
Power up Control Box using transmitter. Open transmitter and Push “MODE” button to select the
“Front Hopper” Mode (First two lights flashing).
2.
Push and hold the “On/Open” and “Off/Closed” buttons on the transmitter simultaneously for 3
seconds or until control box light comes on to indicate the control box is activated.
3.
Select button to perform the required operations for the front hopper.
4.
To use the rear hopper, push “MODE” button to select “Rear Hopper” (First three lights flashing).
5.
Select button to perform the required operations for the rear hopper.
6.
Power off Control Box when finished. Push “MODE” button to select “Front Hopper” Mode (First two
lights flashing). Push and hold the “ON/OPEN” and “OFF/CLOSED” buttons on the transmitter
simultaneously for 3 seconds or until control box light goes off.
EZ Flow Cylinder Disconnect *Emergency Operation*(if equipped)
1.
Locate poppet valve buttons. (Fig A)
a.
Top Button (1) is for front door
b.
Bottom Button (2) is for rear door
2.
Push & hold each button individually for approx. 15
secs or until system is depressurized.
3.
When system has been depressurized, unlatch quick
release pin & remove. (Fig B) Repeat this step on all
cylinders as needed.
4.
Door(s) are now disconnected from the cylinders
and can now be operated manually.
MODE Selection
Button
MODE Lights
ON/OPEN Button
OFF/CLOSED
Button
Poppet Valves
(1)
(2)
Figure A
Figure B