THT-EX L1512D Скачать руководство пользователя страница 5

5

4.2 Mounting Bracket Installation

4.2.1

Adjustable Trunnion (Wall & Ceiling) Mounting -

F

The mount bracket is for surface mounting to wall (Figure 1) or ceiling (Figure 2).

F

Position the bracket holders and secured by means of the provided M8 screws with 122 kgf-cm.

F

Secure the wall/ceiling mounting bracket to the mounting surface by using four fasteners

(

not provided).

F

Mounting Orientation – Lens horizontal Facing Down or Lens Facing Down 45° from vertical. Don’t adjust
the Mounting Orientation as “Lens horizontal Facing Up” position. (Figure 3).

4.2.2

Adjustable Tube Mounting -

F

This mounting bracket type is for mounting unto the straight electrical tube (Figure 4).

F

The assembly of the bracket onto the conduit must be secured with the use of M8 threaded screws and by
applying122.0 kgf-cm torque.

Figure 1

Figure 2

Figure 3

Figure 4