background image

UPSIDE

Pg. 10

GENERAL ASSEMBLY INSTRUCTIONS

 · 

SIZES MAY VARY

DIAGNOSTIC CODES FOR CBD6S

DIAGNOSTIC 

CODES

NAME

DESCRIPTION

CBD4/5/6

EQUIVALENT

POTENTIAL CAUSE

SOLUTION/ 

TROUBLESHOOTING

E33

Ch5 Type

Channel 5 is not same type as 

when initialized

NEW

•  [Reserved for future development]

•  [Reserved for future development]

E34

Ch6 Type

Channel 6 is not same type as 

when initialized

NEW

•  [Reserved for future development]

•  [Reserved for future development]

E35

Ch1 Pulse Fail

Channel 1 had too many pulse 

errors

E24

•  Loose/ faulty cable
•  Hall sensor PCB

•  Check motor cable connections and integrity

 

•  Change Desk Leg
•  Initialize the system

E36

Ch2 Pulse Fail

Channel 2 had too many pulse 

errors

E25

•  Loose/ faulty cable
•  Hall sensor PCB

•  Check motor cable connections and integrity

 

•  Change Desk Leg
•  Initialize the system

E37

Ch3 Pulse Fail

Channel 3 had too many pulse 

errors

E26

•  Loose/ faulty cable
•  Hall sensor PCB

•  Check motor cable connections and integrity

 

•  Change Desk Leg
•  Initialize the system

E38

Ch4 Pulse 

Fail

Channel 4 had too many pulse 

errors

E27

•  Loose/ faulty cable
•  Hall sensor PCB

•  Check motor cable connections and integrity

 

•  Change Desk Leg
•  Initialize the system

E39

Ch5 Pulse Fail

Channel 5 had too many pulse 

errors

NEW

•  [Reserved for future development]

•  [Reserved for future development]

E40

Ch6 Pulse 

Fail

Channel 6 had too many pulse 

errors

NEW

•  [Reserved for future development]

•  [Reserved for future development]

E41

Ch1 

Overload Up

Overload up occurred on Channel 1

E28

•  Leg is overloaded
•  Hit obstruction
•  Reached end stop (before initialization  
    at upper end-stop occurs)

•  Remove obstruction
•  Remove load
•  Initialize if necessary

E42

Ch2 

Overload Up

Overload up occurred on Channel 2

E29

•  Leg is overloaded
•  Hit obstruction
•  Reached end stop (before initialization  
    at upper end-stop occurs)

•  Remove obstruction
•  Remove load
•  Initialize if necessary

E43

Ch3 

Overload Up

Overload up occurred on Channel 3

E30

•  Leg is overloaded
•  Hit obstruction
•  Reached end stop (before initialization  
    at upper end-stop occurs)

•  Remove obstruction
•  Remove load
•  Initialize if necessary

E44

Ch4 

Overload Up

Overload up occurred on Channel 4

E31

•  Leg is overloaded
•  Hit obstruction
•  Reached end stop (before initialization  
    at upper end-stop occurs)

•  Remove obstruction
•  Remove load
•  Initialize if necessary

E45

Ch5 

Overload Up

Overload up occurred on Channel 5

NEW

•  [Reserved for future development]

•  [Reserved for future development]

E46

Ch6 

Overload Up

Overload up occurred on Channel 6

NEW

•  [Reserved for future development]

•  [Reserved for future development]

E47

Ch1 Overload 

DW

Overload down occurred on 

channel 1

E32

•  Hit obstruction

•  Remove obstruction
•  Initialize if necessary

E48

Ch2 Overload 

DW

Overload down occurred on 

channel 2

E33

•  Hit obstruction

•  Remove obstruction
•  Initialize if necessary

E49

Ch3 Overload 

DW

Overload down occurred on 

Channel 3

E34

•  Hit obstruction

•  Remove obstruction
•  Initialize if necessary

E50

Ch4 

Overload DW

Overload down occurred on 

Channel 4

E35

•  Hit obstruction

•  Remove obstruction
•  Initialize if necessary

E51

Ch5 Overload 

DW

Overload down occurred on 

Channel 5

NEW

•  [Reserved for future development]

•  [Reserved for future development]

Содержание UPSIDE

Страница 1: ...UPSIDE Assembly Instructions ...

Страница 2: ... a clean soft surface Place legs in position as shown Secure legs in place using 6 M6x16mm flat socket cap bolt provided for each leg 5 32 Allen Wrench provided 1 Hardware Provided Tools Required M6 x16mm Bolt 20 UPSIDE Pg 1 GENERAL ASSEMBLY INSTRUCTIONS SIZES MAY VARY 1 2 DESK TOP AND LEGS LEG SECURE Place desk top good side down on a clean soft surface Place legs in position as shown Secure legs...

Страница 3: ...g 4 M6 x16mm flat socket cap bolts provided for each plate Once the legs are secured in place and the leg base plates are fasten securely plug the power cords into the legs Turn desk to upright position and plug into to outlet Test the desk by lowering it to the bottom and raising it to the top If the system fails initialization may be required See page 8 ...

Страница 4: ...ly with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access to this User Manual Follow the instructions for mounting risk of injury if these instructions are not followed The appliance is not intended for use by young childr...

Страница 5: ...e mains System connection The individual parts must be connected before the control box is connected to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved The products must only...

Страница 6: ...carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning If any of the DESKLINE products are opened there will be a risk of subsequent malfunction Warning The DESKLINE systems do not withstand cutting oil ...

Страница 7: ... on the control box by means of the motor cables which have an 6 pin plug in each end Please note that the control box must only be connected to the voltage stated on the label Finally the mains cable is to be mounted and power switched on DP WDPL Mains cable DL5 DL6 Hook for cable relief Figure 5 CBD4 CBD5 CBD6 with earth The CBD4 CBD5 CBD6 earth cable to be mounted on the desk construction typic...

Страница 8: ...tle plug called a dongle must be mounted in one of the 2 control ports The function is only active when the dongle is mounted If you remove the dongle again you disable the function Method of operation When the DL DB s are running the CBD4 CBD5 CBD6 monitors the current consumption on each channel using a special algorithm If the current consumption on one channel is increased more than a predefin...

Страница 9: ...ion printed on label E18 Missing Initialization Plug A special service tool is required to change number of channels to the system NEW BASELIFT ONLY Service tool missing from BASELIFT system when initializing Add service tool E23 Ch1 Missing Channel 1 is detected missing E17 Disconnection Faulty motor cable Faulty motor leg Check motor cable connections and integrity Change motor cable or Desk Leg...

Страница 10: ...l 1 E28 Leg is overloaded Hit obstruction Reached end stop before initialization at upper end stop occurs Remove obstruction Remove load Initialize if necessary E42 Ch2 Overload Up Overload up occurred on Channel 2 E29 Leg is overloaded Hit obstruction Reached end stop before initialization at upper end stop occurs Remove obstruction Remove load Initialize if necessary E43 Ch3 Overload Up Overload...

Страница 11: ...Hit obstruction Remove obstruction Initialize if necessary E63 Ch5 SLS PIEZO Safety limit switch activated on Channel 5 NEW Reserved for future development Reserved for future development E64 Ch6 SLS PIEZO Safety limit switch activated on Channel 6 NEW Reserved for future development Reserved for future development E65 Ch1 Pulse Dir Pulses counted wrong direction in Channel 1 E44 Motor poles are c...

Страница 12: ...iture Systems Limited 156462 Clover Valley Rd New Liskeard ON Canada P0J 1P0 T 1 800 767 5374 F 1 888 484 5786 customer service three h com www three h com 2017 Three H Furniture Systems Limited All rights reserved ...

Отзывы: