![Thrane&Thrane Sailor 6081 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/thraneandthrane/sailor-6081/sailor-6081_installation-and-user-manual_1111376040.webp)
33
Chapter 4
4444
Cu
st
om
iz
ing b
a
tter
y
Customizing battery settings
4
Battery settings
To customize some parameters and alarm thresholds use the SAILOR 6006
Message Terminal or a software tool. The communication is via the Ethernet
interface. The following parameters can be changed:
Parameter
Default value
Allowed range
Maximum charging current
a
a. The charging current may be lower depending on the currently
available output power.
8 A
1 A — 40 A
Maximum charging voltage
b
b. All voltages at 20° C. If a temperature sensor is mounted the
voltages are compensated with -36 mV/°C.
28.8 V
26 V — 31 V
Float voltage
b
27.2 V
24 V — 29.5 V
Min. battery alarm voltage
23.5 V
10 V — 30 V
Max. battery alarm voltage
29.5 V
20 V — 35 V
Recharge voltage
c
c.
If the recharge voltage is higher than the float voltage, recharging
starts only when the battery voltage reaches the Recharge voltage
level.
25 V
20 V — 26 V
Min. alarm temperature
d
d. Only relevant if a battery temperature sensor is installed.
-5 °C
-20 — +25 °C
Max. alarm temperature
d
55 °C
+25 — +110 °C
Содержание Sailor 6081
Страница 1: ...INSTALLATION USER MANUAL SAILOR 6081 Power Supply Unit and Charger ...
Страница 39: ...Chapter 3 Service and repair 32 Returning units for repair ...
Страница 43: ...Chapter 4 Customizing battery settings 36 Changing battery settings ...
Страница 61: ...Appendix B Upgrade 54 Upgrading with additional SAILOR 6080 units ...
Страница 63: ...Appendix C Approvals 56 Wheelmark ...
Страница 68: ...98 130980 A Thrane Thrane A S info thrane com www thrane com ...