HOW TO CAUSE EXPENSIVE DAMAGE TO YOUR MACHINE

 

WHAT WAS DONE WRONG:  WHAT WAS THE RESULT OF THIS ACTION: 

Cracked and burnt high pressure seals in pump. 

Machine was allowed to run dry 
(without water supply) 

No. 1 piston cracked due to thermal shock. 

Mechanical damages to EVERYTHING: 

-          Pistol, HP hose, pump valves, pistons 

-          Crankshaft bearing failure 

-          Pressure gauge failure 

-          By-pass valve excessive wear & tear 

-          Frequent O-rings blow outs 

Unit was run on low volume 
water supply and allowed to 
cavitate 

-          Brass heads deformed 

Over adjust by-pass valve to try 
and increase PSI 

Dump pressure was too high. Hydraulic hammer to system every 
time trigger is closed. PSI was increased 5-fold normal working 
pressure. 

Excessive wear & tear on pistons / valves / seals / HP jets. 

Excessive blocking of filters caused by bore or recycled water with 
high salt / mineral content. Pump clogged up with debris. 

In-Line filter was removed 
because “It kept blocking up!” 

Remember: Spec requirement says: “Potable water” 

Over-revved engine for more PSI 

Engine & Pump premature wear & tear. (Most increased PSI  
pressure is lost through by-pass valve and only small increase in 
pressure is achieved doing this!) Lost of waster horse power! 

When orifice is reduced, the PSI will rise and then by-pass valve will 
dump (thinking the pistol is shut). Most extra PSI will be dumped and 
only a slight increase in PSI will be achieved. 

COMMON MISTAKE:

 Put a 

smaller HP Jet onto lance for 
higher pressure.

 

Engine, By-pass valve & Pump premature wear & tear.   

Using Contaminated Fuel (“Had 
to remove fuel filter to keep 
engine running!”) 

Excess Fuel-system clean-outs required. If excessive corrosion in 
carburetor or injectors is detected after the 2nd or 3rd in-line fuel 
filter replacement, then this should ring alarm bells. 

Park machine where debris 
blows all over it. Reverse 
bulldozer over it. 

Our machines are rugged and strong – but not battle tanks! 

Hire units long-terms and fluid 
levels are not checked. 

Con-rod through the crank case! 

Modify 240 Volt electric unit to 
override thermal overload on 
motor. 

Stop-Start capacitors melted. 

Used 100m extension lead and a 
5 Kva Gen-Set. 

A 10% low current is equivalent to a 50% over-load. 

  

Our 3 hp 240 Volt motors require 8 Kva Gen-Set minimum! 

Run trucks, fork-lifts, tracked 
excavation equipment over 
hoses and lance 
assemblies/pressure guns. 

Needs replacing of damaged parts 

Содержание D10M-36H

Страница 1: ...ical data Specifications 3 Installation Start up 4 Operating Tips Shutting down Regular Checks 6 7 Maintenance Schedule 8 9 Trouble Shooting Guide 10 What can cause expensive damage to your machine 11...

Страница 2: ...R NPM1525R NPM1525R NPM1525R Old HAWK pump model HC456 HC456 HC456 HC456 Max Pressure Flow 3625 psi 15 lpm 3625 psi 15 lpm 3625 psi 15 lpm 3625 psi 15 lpm Set up de rated pressure flow 3000 psi 15 lpm...

Страница 3: ...l not more If oil need to be topped up use SAE10W40 or SAE 15W40 or SAE30 and top up at the Slave Oil Tank if fitted otherwise on the pump itself Ensure water supply tap on portable machines or tank b...

Страница 4: ...gent by spraying from bottom up to avoid streaking using a dual lance and detergent assembly Allow to soak for a few minutes 3 Blast off dirt using high pressure and a bottom up approach 4 Lastly rins...

Страница 5: ...n to prevent damage o Automatic dumping of hot water when water temp rises above 63 deg C Worn By Pass Valves Soft Acting By Pass valves should NOT store high pressure water in hose down stream betwee...

Страница 6: ...and Refurbish pump Replace Plunger Rod Oil Seals 3 pump Replace Brass Valves 6 pump Replace various seals 3 pump Replace Ceramic Piston Plungers if cracked or worn 3 pump Only if required 11 Check By...

Страница 7: ...time to replace the seals on the pump using a Seal Kit At the same time also replace the seals on the By Pass Valve using a By Pass kit or if economically viable replace by pass valve By Pass Valves w...

Страница 8: ...ocked Cavitation or air in the system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the...

Страница 9: ...Piston Seals Worn Cracked Piston Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Wor...

Страница 10: ...lost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Страница 11: ...s bearings on shafts where water penetration would be detrimental NEVER WATER BLAST fragile items surfaces that may be damaged by high velocity water Always carefully test on a small area first ALWAYS...

Страница 12: ...cial note of any chemicals that were used and the quality of the water MEDIC ALERT INFORMATION ALWAYS ENSURE MACHINE IS FITTED WITH A REMOVEABLE MEDICAL ALERT WARNING TAG AND TAKE THIS TO A MEDICAL PR...

Страница 13: ...able loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits to the consum...

Страница 14: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Страница 15: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Страница 16: ...6 38 37 34 26 40 41 42 1 29 33 6 10 9 8 13 12 14 20 19 11 43 44 45 48 31 32 23 16 25 30 15 16 17 18 27 46 47 24 3 28 7 4 2 26 25 23 16 21 22 13 14 11 18 12 5 Hawk NPM1525 serie 2011 NPM1525 pump 2011...

Страница 17: ......

Страница 18: ...02 00 Valve plate 6 21 0900 30 Valve spring 6 22 0604 05 Valve cage 6 23 1802 03 Hexagonal screw M8x18 8 24 0500 61 Closed bearing housing 1 25 0601 63 O Ring 1 78x60 05 2 26 0200 06 Roller bearing 33...

Страница 19: ...Seals 18 mm 1 2600 37 Complete Seals Packing 18 mm 3 2612 42 Plunger 18 mm 3 2600 08 Complete Valve 6 2608 03 Plunger oil Seals 1 2600 75 Complete Manifold 1 3100 13 Connecting Rod Plunger Rod Assy 3...

Страница 20: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Страница 21: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Страница 22: ......

Страница 23: ...B 25A FUSE 15A E STOP OFF ON START STARTER SOL NEGATIVE R1 WATER R3 R3 WATERFAULT LIGHT R2 OIL ENGINEFAULT LIGHT H M A FUEL SOL OIL OFF ON BURNER R4 FLOW PRESSURE R5 R4 R4 FAN M IGN M START SOL WATERF...

Отзывы: