background image

 
 

 

 

FEATURES 

 

 

Measures voltage, current, power (W), 
charge meter (Ah), energy (Wh), and 
temperature 

 

Operates at up to 32V and 500A of 
continuous current using the integrated 
current shunt 

 

Data logging for up to 3 years 

 

Can drive one relay or SSR (solid-state relay) 

 

Low / high voltage disconnect 

 

Over-current disconnect 

 

Low / high temperature disconnect 

 

Generator control  

 

Battery monitor (battery fuel gauge), 
displays the state of charge in percentage 
and the remaining time on battery at 
current load 

 

Works with all types of batteries 

 

Timers 

 

Can use an external temperature sensor 
(DS18B20 based) 

 

User / master password protection 

 

Very low power consumption (see 
Performance Parameters) 

 

Bluetooth LE radio with internal antenna 
and long range 

 

Measures only 3.25

” x 1.

75

” x 

1

.75” 

(82mm 

x 45mm x 45mm) including  

 

Weatherproof 

 

Free PowerMonX app is available for 
Android and iOS.  

 

Most parameters can be configured, 
allowing it to achieve top performance with 
all kinds of batteries

 

 

 

TYPICAL APPLICATIONS 

 

RVs, boats, off-the-grid cabins 

 

Solar and wind alternative energy systems 

 

Vehicle batteries 

 

Backup electrical systems 

 

Automation: solar irrigation systems, solar streetlights, general-purpose DC timers 

 

 

 

 

Содержание PowerMon-5S

Страница 1: ...1 PowerMon 5S Bluetooth Low Energy 500A Advanced Battery Monitor DC Power Meter USER MANUAL...

Страница 2: ...e device can log the data for up to 3 years allowing for advanced data analysis and troubleshooting All battery monitors on the market that log data do it inside the mobile application but PowerMon 5S...

Страница 3: ...orks with all types of batteries Timers Can use an external temperature sensor DS18B20 based User master password protection Very low power consumption see Performance Parameters Bluetooth LE radio wi...

Страница 4: ...round Connect using the supplied black wire to the battery negative 3 10mm hex bolt LOAD Connect to the loads charger solar charge controller 4 blade male terminal RELAY Relay output It drives a mecha...

Страница 5: ...current through the RELAY terminal maximum relay coil current 2A Maximum current through the shunt 500A continuous Operating temperature 30 C to 85 C 1 Stresses greater than those listed under Absolut...

Страница 6: ...ithout calibration 0 25 with calibration Temperature 1 C 1 F resolution Data logging sample rate 1 sec up to 18 days 2 sec up to 36 days 5 sec up to 90 days 10 sec up to 180 days 20 sec up to 1 year 3...

Страница 7: ...xemption This system has been evaluated for RF Exposure per RSS 102 and is in compliance with the limits specified by Health Canada Safety Code 6 L exposition aux radiofr quences de ce syst me a t val...

Страница 8: ...istance to the elements Warning The device is to be connected to DC circuits only not exceeding 32V and 500A Failure to do so will result in equipment damage Confirm that all connections are tight to...

Страница 9: ...5S device the value displayed may have a small offset measurement is different than zero even when the actual current is zero Typically this is less than 0 1A In situations where the measurement prec...

Страница 10: ...t threshold and will reconnect the load when the voltage goes below the reconnect threshold This mode can be used together with the low voltage disconnect Over current disconnect When this feature is...

Страница 11: ...timer does not need to have both the start and stop times One of them can be disabled This kind of timer should be used in pairs one turns the relay on and the second one turns it off Repetition cont...

Страница 12: ...The time left before the battery is completely discharged assuming the current rate of discharge This value is only shown when the discharge current is higher than 0 1A Power Status Displays the curre...

Страница 13: ...minal when the power is on the RELAY terminal will be floating and when the power is off it will be driven to the ground BATT When this option is enabled Trigger on Relay Active is ignored disabled Co...

Страница 14: ...re above which the power relay can re engage after the connect filter time has passed This must be higher than LTD Disconnect Threshold LTD Disconnect Filter milliseconds The duration of time the temp...

Страница 15: ...OFF when the battery state of charge becomes lower than this threshold in percentage Connect on Battery SoC Threshold The device will re connect power turn the relay ON when the battery state of charg...

Страница 16: ...f a custom system using the PowerMon 5S battery monitor can use the master password to protect those critical areas of the configuration The critical areas protected by the master password can be unlo...

Страница 17: ...17 Renaming the device Renaming the device can be achieved using the top right menu button and taping on Device Information The maximum name length is 8 characters...

Страница 18: ...fore the relay This is done so they cannot be disconnected from the battery during a low voltage or other disconnect events very important for an MPPT charge controller The main fuse should be sized b...

Страница 19: ...19 DIMENSIONS Dimensions are in mm...

Страница 20: ...20 ORDERING Part Number Description PowerMon 5S PowerMon 5S Bluetooth LE 500A Advanced Battery Monitor DC Power Meter...

Отзывы: