PWA120 Adapter Plate for 1.5” Post Accessories
Chapter 2: Installation
Page 8
ETN056632-D02
2.7.
Installing Other Accessories
Caution:
To avoid a risk of tipping the frame…
Do not push/pull laterally on the posts as this may cause the table frame to tip over.
High loads should be placed in a low position, otherwise the stability of the frame could be affected.
The center-of-mass of the experimental setup as a whole, should remain within the frame area.
Do not exceed the vertical load capacity of 40 kg (88 lbs) for each adapter plate.
The adapter plates can also be used to fit both imperial and metric breadboards or other accessories, using
the 4 M6 (1/4”) clearance holes shown below.
Figure 6 Clearance Holes in Adapter Plates