THORLABS PDP90A Скачать руководство пользователя страница 2

Lateral Effect Position Sensor 

 

Page 1

 

Rev G, May 11, 2017

 

Table of Contents

 

Chapter 1

 

Warning Symbol Definitions ........................................... 2

 

Chapter 2

 

Description ........................................................................ 3

 

2.1.

 

Setup

 

Instructions

 

..........................................................

 

3

 

2.2.

 

Details

 

of

 

Operation

 

......................................................

 

3

 

2.2.1.

 

Overview ...................................................................................... 4

 

2.2.2.

 

Calculating the Position ............................................................... 4

 

2.2.3.

 

Position Resolution ...................................................................... 5

 

Chapter 3

 

Specifications ................................................................... 7

 

Chapter 4

 

Regulatory ......................................................................... 9

 

Chapter 5

 

Thorlabs Worldwide Contacts....................................... 10

 

 
 

Содержание PDP90A

Страница 1: ...PDP90A Position Sensing Detector User Guide...

Страница 2: ...er 1 Warning Symbol Definitions 2 Chapter 2 Description 3 2 1 Setup Instructions 3 2 2 Details of Operation 3 2 2 1 Overview 4 2 2 2 Calculating the Position 4 2 2 3 Position Resolution 5 Chapter 3 Sp...

Страница 3: ...escription Direct Current Alternating Current Both Direct and Alternating Current Earth Ground Terminal Protective Conductor Terminal Frame or Chassis Terminal Equipotentiality On Supply Off Supply In...

Страница 4: ...position sensing detector An AS4M8E M4 to 8 32 thread adapter is included for customers using metric opto mechanics b Connect the sensor to a KPA101 K Cube Auto Aligner c Follow the directions in the...

Страница 5: ...ed resistive layers significantly increase manufacturing cost Tetra lateral sensors use a single resistive layer with a common cathode and an anode on each side of the detection area This makes them v...

Страница 6: ...00 Vrms where R is the resolution LX is the detector length 10 mm en is the output noise voltage 300 Vrms and V0 is the SUM output voltage level 4 V 10 mm 0 75 m For best results V0 should be maximize...

Страница 7: ...ion of 16 bits with an input voltage range of 15 V 30 V range or a voltage resolution of 30 2 0 458 100 From this the minimum power required can be determined based on the required accuracy For exampl...

Страница 8: ...er Requirements 5 VDC 5 35 mA Physical Specifications Sensor Size 9 mm x 9 mm 0 35 x 0 35 Mechanical Aperture 0 50 12 7 mm Aperture Thread Internal SM05 0 535 40 Dimensions 2 00 x 1 20 x 0 65 50 8 mm...

Страница 9: ...5 mm 1 20 50 8 mm 2 00 9 0 mm 0 35 9 0 mm 0 35 15 2 mm 0 60 3 05 mm 0 12 Front Side Housing to Sensor 3 2 1 4 5 6 Detail A Scale 2 1 D A B C 15 2 mm 0 60 0 50 Clear Aperture SM05 Threaded 16 5 mm 0 6...

Страница 10: ...ducts such as Pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards Components Mechanics and optics Left over parts of units disassembled by the user P...

Страница 11: ...ope thorlabs com Scandinavia Thorlabs Sweden AB Bergfotsgatan 7 431 35 M lndal Sweden Tel 46 31 733 30 00 Fax 46 31 703 40 45 www thorlabs com Email scandinavia thorlabs com France Thorlabs SAS 109 ru...

Страница 12: ...www thorlabs com...