The OSW12(22)-xxxE Series of Switch Kits include a MEMS optical switch with an integrated
control circuit that includes an USB 2.0 interface for easy integration into your optical system. It
is available as 1x2 or 2x2 (1x4 and 1x8 on request) MEMS modules with operating wavelengths
of 488, 633, 780, 830, 980, or 1310 and 1550 nm. These bi-directional switches have low inser-
tion loss and excellent repeatability. The switching mechanism is based on silicon MEMS tech-
nology,  which  ensures  high  reliability,  provides  exceptionally  low  crosstalk  between  channels,
and is inherently very fast (switching time <1ms). 

The OSW12(22)-xxxE switches are designed for the distribution and routing of signals at the in-
dicated visible or near infrared wavelengths. The switches can be controlled via USB2.0 by the
included GUI and driver package, via an on-board toggle switch, or via BNC input  (TTL signal).
 A seven segment LED display indicates the active channel.

By default, all switches are shipped without fiber connectors. Termination of the fibers is avail-
able upon request; please contact your local Thorlabs office or distributor for pricing. Addition-
ally, 1x4 and 1x8 MEMS switch modules are available on request. 

The OSW12(22)-xxxE Series Switch Kits can be powered via the USB port or the onboard DC
power connector. 

A universal 9 V wall power supply is included with these Switch Kits.

1.1   Safety

 Attention 

All statements regarding safety of operation and technical data in this instruction manual
will only apply when the unit is operated correctly as it was designed for.

The OSW12(22)-xxxE must not be operated in explosion endangered environments!

Only  with  written  consent  from 

Thorlabs  GmbH

  may  changes  to  single  components  be

made or components not supplied by 

Thorlabs GmbH

 be used. 

This  precision  device  is  only  serviceable  if  properly  packed  into  the  complete  original
packaging. If necessary, ask for a replacement package prior to return.

 Warning 

 

When operating this unit with a laser be sure to pay strict attention to the safety recom-
mendations of the appropriate laser safety class of the used laser!

When operated incorrectly, this can cause severe damage to your eyes and health! 
Do not look directly into any of the optical fiber terminations. 

Cover any unused fiber termination.

 Attention 

The OSW12(22)-xxxE module is electrostatic discharge sensitive.
Observe the precautions for handling ESD sensitive modules.

 Attention 

Mobile telephones, cellular phones or other radio transmitters are not to be used within
the range of three meters of this unit since the electromagnetic field intensity may then
exceed the maximum allowed disturbance values according to IEC 61326-1.

This  product  has  been  tested  and  found  to  comply  with  the  limits  according  to
IEC 61326-1 for using connection cables shorter than 3 meters (9.8 feet).

Содержание OSW12 E Series

Страница 1: ...MEMS Fiber Optic Switch Kits OSW12 22 xxxE Operation Manual 2018...

Страница 2: ...Version Date Copyright 2018 Thorlabs GmbH 3 5 12 Jul 2018...

Страница 3: ...2 Operating the OSW22 yyyyE 9 3 3 Operating the OSW14 yyyyE Option 9 3 4 Operating the OSW18 yyyyE Option 4 Computer Interface 10 10 4 1 Interface Setup 10 4 2 Message Exchange 10 4 3 Command Descript...

Страница 4: ...international partners are looking forward to hearing from you Thorlabs GmbH Warning Sections marked by this symbol explain dangers that might result in personal injury or death Always read the assoc...

Страница 5: ...oard DC power connector A universal 9 V wall power supply is included with these Switch Kits 1 1 Safety Attention All statements regarding safety of operation and technical data in this instruction ma...

Страница 6: ...only 1 3 Requirements These are the requirements to the PC intended to be used for remote operation of the OSW12 22 xxxE 1 3 1 Hardware Requirements CPU 1 GHz or higher RAM 256 MB Graphic card Min 32...

Страница 7: ...cted the OSW12 22 xxxE mechanically and electrically Verify that you have received the following items within the package 1 OSW12 yyyyE or OSW22 yyyyE Optical Switch with electronic board 2 Wall Power...

Страница 8: ...bar state 2 1 4 2 cross state 2 1 3 For OSW22 switches 1 bar state 2 1 4 1 1 3 2 cross state 2 1 3 1 1 4 3 S1 Manual Toggle Switch 4 Jumpers JP5A JP5D see section Interface Setup 5 CON8 USB Connector...

Страница 9: ...into the corre sponding DC power jack Connect a high quality regulated power supply with 6V 15V DC output capable of deliver ing a current of min 300mA to the coaxial DC power jack CON5 Use a standard...

Страница 10: ...te is indicated by the state signals SW_STAT 0 7 at the pins C19 C12 of the 64 pin connector 3 2 Operating the OSW22 yyyyE Once the power supply is connected the 7 Segment display shows 1 and the opti...

Страница 11: ...The actual switch state is indicated by the state signals SW_STAT 0 7 at the pins C19 C12 of the 64 pin connector 3 4 Operating the OSW18 yyyyE Option Once the power supply is connected the 7 Segment...

Страница 12: ...e Exchange The OSW12 22 xxxE board uses a simple human readable command structure A program message consists of a command parameters depending on the command and a program mes sage terminator LF Line...

Страница 13: ...case of a SN 1x2 switch the following response will be generated 0 CR LF Query OSW board name Command I Parameter None Response OSW board name and version Description Queries the OSW name and the firm...

Страница 14: ...r resistant Attention To avoid damage to the instrument do not expose it to spray liquids or solvents The unit does not need a regular maintenance by the user It does not contain any modules and or co...

Страница 15: ...310E Single Mode Corning SMF 28E MFD 9 2 m 1310 nm MFD 10 4 m 1550 nm Connectors none or on request Optical Power OSWxx 488E max 30 mW OSWxx 633E max 50 mW OSWxx 780E max 75 mW OSWxx 830E max 85 mW OS...

Страница 16: ...03 2 BNC Connector TTL switching signal Operating Voltage 4 75 5 25 V DC 300 mA USB Connector or 6 15 V DC 300 mA DC Power Connector Wall Power Supply included 90 264 V AC 9 V DC 1 1 A Supply Current...

Страница 17: ...2018 Thorlabs GmbH 6 Appendix 15 6 2 Pin Assignment CON4 For explanation of SW_STAT0 SW_STAT7 please see section Switch States 16...

Страница 18: ...on State Signal SW_STATn 7 6 5 4 3 2 1 0 1 Bare State 11 3 21 4 GND GND 5V GND GND GND GND 5V 2 Cross State 11 4 21 3 GND GND GND 5V GND GND 5V GND OSW14 E 1x4 Option State Description State Signal SW...

Страница 19: ...8 Thorlabs GmbH 6 Appendix 17 6 4 Switch Outline Drawings Pin Layout SN1x2 MEMS Switch Component for OSW12 Pin Layout SN2x2 MEMS Switch Component for OSW22 Pin Layout SN1x4 MEMS Switch Component for O...

Страница 20: ...2018 Thorlabs GmbH 18 OSW12 22 xxxE Pin Layout Sw1x8 MEMS Switch Component for OSW18...

Страница 21: ...and or software determined by Thorlabs GmbH for this unit to operate fault free provided that they are handled according to our requirements However Thorlabs GmbH does not warrant a fault free and un...

Страница 22: ...ined in this document Should you require further information on this product or encounter specific problems that are not dis cussed in sufficient detail in the document please contact your local Thorl...

Страница 23: ...8 Ecological background It is well known that waste treatment pollutes the environment by releasing toxic products dur ing decomposition The aim of the European RoHS Directive is to reduce the content...

Страница 24: ...a Thorlabs Inc sales thorlabs com techsupport thorlabs com Europe Thorlabs GmbH europe thorlabs com France Thorlabs SAS sales fr thorlabs com Japan Thorlabs Japan Inc sales thorlabs jp UK and Ireland...

Отзывы: