MEMS Fiber Optic Switch Kits
OSW12(22)-xxxEOperation Manual
2018
Страница 1: ...MEMS Fiber Optic Switch Kits OSW12 22 xxxE Operation Manual 2018...
Страница 2: ...Version Date Copyright 2018 Thorlabs GmbH 3 5 12 Jul 2018...
Страница 3: ...2 Operating the OSW22 yyyyE 9 3 3 Operating the OSW14 yyyyE Option 9 3 4 Operating the OSW18 yyyyE Option 4 Computer Interface 10 10 4 1 Interface Setup 10 4 2 Message Exchange 10 4 3 Command Descript...
Страница 4: ...international partners are looking forward to hearing from you Thorlabs GmbH Warning Sections marked by this symbol explain dangers that might result in personal injury or death Always read the assoc...
Страница 5: ...oard DC power connector A universal 9 V wall power supply is included with these Switch Kits 1 1 Safety Attention All statements regarding safety of operation and technical data in this instruction ma...
Страница 6: ...only 1 3 Requirements These are the requirements to the PC intended to be used for remote operation of the OSW12 22 xxxE 1 3 1 Hardware Requirements CPU 1 GHz or higher RAM 256 MB Graphic card Min 32...
Страница 7: ...cted the OSW12 22 xxxE mechanically and electrically Verify that you have received the following items within the package 1 OSW12 yyyyE or OSW22 yyyyE Optical Switch with electronic board 2 Wall Power...
Страница 8: ...bar state 2 1 4 2 cross state 2 1 3 For OSW22 switches 1 bar state 2 1 4 1 1 3 2 cross state 2 1 3 1 1 4 3 S1 Manual Toggle Switch 4 Jumpers JP5A JP5D see section Interface Setup 5 CON8 USB Connector...
Страница 9: ...into the corre sponding DC power jack Connect a high quality regulated power supply with 6V 15V DC output capable of deliver ing a current of min 300mA to the coaxial DC power jack CON5 Use a standard...
Страница 10: ...te is indicated by the state signals SW_STAT 0 7 at the pins C19 C12 of the 64 pin connector 3 2 Operating the OSW22 yyyyE Once the power supply is connected the 7 Segment display shows 1 and the opti...
Страница 11: ...The actual switch state is indicated by the state signals SW_STAT 0 7 at the pins C19 C12 of the 64 pin connector 3 4 Operating the OSW18 yyyyE Option Once the power supply is connected the 7 Segment...
Страница 12: ...e Exchange The OSW12 22 xxxE board uses a simple human readable command structure A program message consists of a command parameters depending on the command and a program mes sage terminator LF Line...
Страница 13: ...case of a SN 1x2 switch the following response will be generated 0 CR LF Query OSW board name Command I Parameter None Response OSW board name and version Description Queries the OSW name and the firm...
Страница 14: ...r resistant Attention To avoid damage to the instrument do not expose it to spray liquids or solvents The unit does not need a regular maintenance by the user It does not contain any modules and or co...
Страница 15: ...310E Single Mode Corning SMF 28E MFD 9 2 m 1310 nm MFD 10 4 m 1550 nm Connectors none or on request Optical Power OSWxx 488E max 30 mW OSWxx 633E max 50 mW OSWxx 780E max 75 mW OSWxx 830E max 85 mW OS...
Страница 16: ...03 2 BNC Connector TTL switching signal Operating Voltage 4 75 5 25 V DC 300 mA USB Connector or 6 15 V DC 300 mA DC Power Connector Wall Power Supply included 90 264 V AC 9 V DC 1 1 A Supply Current...
Страница 17: ...2018 Thorlabs GmbH 6 Appendix 15 6 2 Pin Assignment CON4 For explanation of SW_STAT0 SW_STAT7 please see section Switch States 16...
Страница 18: ...on State Signal SW_STATn 7 6 5 4 3 2 1 0 1 Bare State 11 3 21 4 GND GND 5V GND GND GND GND 5V 2 Cross State 11 4 21 3 GND GND GND 5V GND GND 5V GND OSW14 E 1x4 Option State Description State Signal SW...
Страница 19: ...8 Thorlabs GmbH 6 Appendix 17 6 4 Switch Outline Drawings Pin Layout SN1x2 MEMS Switch Component for OSW12 Pin Layout SN2x2 MEMS Switch Component for OSW22 Pin Layout SN1x4 MEMS Switch Component for O...
Страница 20: ...2018 Thorlabs GmbH 18 OSW12 22 xxxE Pin Layout Sw1x8 MEMS Switch Component for OSW18...
Страница 21: ...and or software determined by Thorlabs GmbH for this unit to operate fault free provided that they are handled according to our requirements However Thorlabs GmbH does not warrant a fault free and un...
Страница 22: ...ined in this document Should you require further information on this product or encounter specific problems that are not dis cussed in sufficient detail in the document please contact your local Thorl...
Страница 23: ...8 Ecological background It is well known that waste treatment pollutes the environment by releasing toxic products dur ing decomposition The aim of the European RoHS Directive is to reduce the content...
Страница 24: ...a Thorlabs Inc sales thorlabs com techsupport thorlabs com Europe Thorlabs GmbH europe thorlabs com France Thorlabs SAS sales fr thorlabs com Japan Thorlabs Japan Inc sales thorlabs jp UK and Ireland...