THORLABS MMR601 Скачать руководство пользователя страница 12

12

Chapter 3

Installation and Set Up

3.1

Installing APT Software

DO NOT CONNECT THE CONTROLLER TO YOUR PC YET

1) Insert the CD into your PC.

2) The CD should run automatically. If your CD does not start, double click the file

‘autorun.exe’, found on the Software CD.

3) A Welcome dialogue screen is displayed. Before installing the software, you are

strongly advised to read the Installation Guide. Click the associated link.

4) Once you are familiar with the installation procedure, click the ‘Install APT

Software’ hyperlink displayed on the Welcome dialogue screen.

5) Follow the on-screen instructions.

Note

When operating via a PC, direct user interaction with the unit is 

accomplished through intuitive graphical user interface panels (GUIs), 

which expose all key operating parameters and modes. The user can 

select multiple panel views displaying different information about a 

particular hardware unit. The multitasking architecture ensures that the 

graphical control panels always remain live, showing all current 

hardware activity.

Caution

Some PCs may have been configured to restrict the users ability to load 

software, and on these systems the  software may not install/run. If you are 

in any doubt about your rights to install/run software, please consult your 

system administrator before attempting to install.

If you experience any problems when installing software, contact Thorlabs on 

+44 (0)1353 654440 and ask for Technical Support.

Содержание MMR601

Страница 1: ...MMR601 MMR602 APT Modular Rack User Guide...

Страница 2: ...General Precautions 13 3 3 Mechanical Installation 14 3 4 Electrical Installation 16 3 5 System Setup 17 3 6 Assigning a Serial Number 18 Chapter 4 Preventive Maintenance 19 4 1 Safety Testing 19 4 2...

Страница 3: ...when there is a risk of injury from electrical shock Warning Given when there is a risk of injury to users Caution Given when there is a risk of damage to the product Note Clarification of an instruc...

Страница 4: ...dy for installation into a standard 19 in frame The MMR602 is supplied with a cover and rubber feet for benchtop use 2 1 2 Building Larger Scale Systems The unrestricted configuration flexibility offe...

Страница 5: ...from the same kernel of ActiveX multithreaded server code and associated suite of high level user applications used to drive our range of APT stand alone bench top controllers This makes it possible t...

Страница 6: ...SB communications and multithreaded execution to enhance system operation and prevent GUI deadlock Rather than a single monolithic entity the APT Server is actually an interoperating collection of Act...

Страница 7: ...epper motor Control to move a motor the progress of that move is reflected automatically by changing position readouts on the graphical interface without the need for further programming intervention...

Страница 8: ...rations such as motor moves can be initiated For many users the APTUser application provides all of the functionality necessary to operate the APT hardware without the need to develop any further cust...

Страница 9: ...e settings have global effect such as switching between simulator and real operating mode associating mechanical stages to specific motor actuators and incorporation of calibration data The APTConfig...

Страница 10: ...enabled In the case of the motor controllers disabling the channel allows the motor actuator to be operated manually Disabling channels on piezo and NanoTrak controllers sends their respective HV out...

Страница 11: ...power supply ground USB USB port for system communications with a host control PC USB Fuse Rating T15A Antisurge Ceramic Modular Rack apt Power Input 800 VA 100 240 VAC 47 63 Hz bonding point EXT IN P...

Страница 12: ...ia a PC direct user interaction with the unit is accomplished through intuitive graphical user interface panels GUIs which expose all key operating parameters and modes The user can select multiple pa...

Страница 13: ...he unit should not be exposed to corrosive agents or excessive moisture heat or dust If the unit has been stored at a low temperature or in an environment of high humidity it must be allowed to reach...

Страница 14: ...with the back plane connector If the module does not go in easily check it lines up with the connector and that the guide rails are positioned correctly Firm pressure is required to seat the module co...

Страница 15: ...US ER I O DR IVE CH AN NE L 1 DR IVE CH AN NE L 2 PIE ZO IN EX TIN HV OU T EX T IN EX T IN Mo del No MP Z6 01 HV OU T EX T IN PIE ZO IN US ER I O DR IVE CH AN NE L 1 DR IVE CH AN NE L 2 PIE ZO IN EX T...

Страница 16: ...for the live feed and one for the neutral as follows When replacing fuses 1 Switch off the power and disconnect the power cord before removing the fuse cover Shock Warning The unit must be connected o...

Страница 17: ...haracteristics of the stage being driven e g min and max positions leadscrew pitch homing direction etc To assist in setting these parameters correctly it is possible using the APT Config utility to a...

Страница 18: ...used by the Server to enumerate and communicate independently with multiple hardware units connected on the same USB bus Before an ActiveX control can communicate with the associated hardware unit the...

Страница 19: ...y personnel authorized by Thorlabs Ltd and trained in the maintenance of this equipment should remove its covers or attempt any repairs or adjustments Maintenance is limited to safety testing and clea...

Страница 20: ...x D x H 480 x 448 x 183 mm 19 0 x 17 6 x 7 0 in 5 2 Associated Products Description Part number APT Modular Rack no cover MMR601 APT Modular Rack with cover MMR602 Modular Rack Handbook ha0117T Thorl...

Страница 21: ...f not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful i...

Страница 22: ...rlabs or your nearest dealer for further information 6 2 2 Waste treatment on your own responsibility If you do not return an end of life unit to the company you must hand it to a company specialized...

Страница 23: ...labs de email sales uk thorlabs com Support techsupport uk thorlabs com France Thorlabs SAS 109 rue des C tes 78600 Maisons Laffitte France Tel 33 0 970 444 844 Fax 33 0 811 381 748 www thorlabs de em...

Страница 24: ...d Saint Thomas Place Ely Cambridgeshire CB7 4EX UK Tel 44 0 1353 654440 Fax 44 0 1353 654444 www thorlabs com Thorlabs Inc 56 Sparta Avenue Newton NJ07860 USA Tel 1 973 579 7227 Fax 1 973 300 3600 www...

Отзывы: