THORLABS LSS10 Скачать руководство пользователя страница 6

Page 4

ETN037435-D02

LSS10  LED Light Box

Chapter 3

Installation

3.1

Mechanical Installation

The lightbox can be permanently fixed to a wall, via the four mounting holes in the rear

panel  - see the dra

wings  available  from  www.thorlabs.com  for  details  and

dimensions.

Furthermore, several metalwork knockouts are provided for grommets (supplied) and

cables when hard wiring the unit into an electrical system.

3.2

Electrical Connections

The unit is connected to the mai ns power using the cable supplied, via the IEC 14

connector on the right hand side - see Fig. 3.1.

Caution

 Screws or fittings to attach the unit to the wall are not included. Always choose

M4 (8-32) screws and fittings which are suitable for use in your wall and have

enough holding power. Do not use screws with countersunk heads. If you are

uncertain, contact a specialised installer.

Note

The default configuration and labelling is for right-handed use, however the mounting 

holes allow the unit to be mounted for left hand use.

Caution

The unit must be fixed securely to the wall before using the internal wiring option. 

Do not use the internal wiring option when the unit is fixed via the keyed slots in 

the rear panel.

Warning

The unit uses mains voltages. This is hazardous and can cause serious injury.

The unit must be installed only by suitably trained and qualified personnel who

understand  the ha zards  associated  with  using  high  voltages  and  the steps

necessary to minimize the risk of electrical shock.

Warning

If using a power cord other than that supplied, ensure that the cord is at least

equivalently  rated  (see Se ction  5.1. fo r  power  cord  ratings) an d  does  not

exceed 3m in length.
Use only power cords with a factory supplied moulded IEC C13 connector. Do

not use cords fitted with rewirable connectors.

Содержание LSS10

Страница 1: ...LSS10 LED Lightbox for Laser Safety Signs User Guide Original Instructions...

Страница 2: ...1 Control and Connection Overview 8 4 2 Using the Safety Interlock 9 4 3 Replacing the Internal Fuses 10 4 4 Inserting a Laser Safety Sign 10 4 5 Disabling the Brightness Control 11 4 6 Cleaning 11 C...

Страница 3: ...2 that prevent the use of interlock equipped laser systems unless the safety light is turned on The external interlock socket accepts a 2 5 mm phono jack supplied The lightbox is permanently fixed to...

Страница 4: ...rom electrical shock Warning Given when there is a risk of injury to users Caution Given when there is a risk of damage to the product Note Clarification of an instruction or additional information Wa...

Страница 5: ...nd can cause serious injury Appropriate care should be taken when using this device Persons using the device must understand the hazards associated with using high voltages and the steps necessary to...

Страница 6: ...s If you are uncertain contact a specialised installer Note The default configuration and labelling is for right handed use however the mounting holes allow the unit to be mounted for left hand use Ca...

Страница 7: ...unit should be hard wired only when it is permanently attached to the wall Only use 3 core 0 75 to 1 5 mm2 218 318 cable to EN 50525 2 11 to hard wire the unit Grommets with a flammability rating of U...

Страница 8: ...on is disconnected at the next step Fig 3 2 Removing the front panel 4 Unclip the connection to the LED circuit CON4 see Fig 3 3 then remove the panel 5 Ensure mains power is disconnected then move th...

Страница 9: ...Fig 3 4 Fig 3 4 Cable knock outs and strain relief clamp locations 7 If using an internal safety interlock perform the procedure detailed in Section 4 2 8 Re connect the LED circuit at CON4 9 Refit th...

Страница 10: ...rols overview BRIGHTNESS Used to control the light intensity of the lightbox when the external controls see Section 4 5 are enabled INTLK For use in laser safety applications see Section 4 2 POWER Use...

Страница 11: ...ceed 34V DC AC 0 5A and should be electrically isolated from hazardous circuits with reinforced insulation External connection is achieved via the jack socket on the right hand control panel see Fig 4...

Страница 12: ...be replaced as follows 1 Remove power from the unit 2 Remove the front panel see Fig 3 2 3 Locate the broken fuse see Fig 3 3 4 Replace the fuse with another of the same type 0 63A T 250 VAC 5 Refit t...

Страница 13: ...ternal control is bypassed and brightness is set internally 1 Isolate the unit from mains power 2 Remove the front Panel see Fig 3 2 3 Move switch SW3 to the INT position as shown below Warning The in...

Страница 14: ...ghtly dampened with water or a mild detergent Note The MIN setting corresponds to the brightness level set to minimum using the control panel pot Similarly the MAX setting corresponds to the max brigh...

Страница 15: ...wer 8W Minimum Brightness to 15 W Max Brightness Internal Fuses Qty 2 0 63A T 250 VAC Operating Temperature Range 5 to 40 C Dimensions W x D x H 362 0 x 257 x 50 mm 14 25 x 10 12 x 1 97 Weight 3 3 Kg...

Страница 16: ...harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with th...

Страница 17: ...Rev A Nov 2017 Page 15 Chapter 6 Regulatory 6 2 CE Certificate...

Страница 18: ...il sales thorlabs com Support techsupport thorlabs com Europe Thorlabs GmbH Hans B ckler Str 6 85221 Dachau Munich Germany Tel 49 0 8131 5956 0 Fax 49 0 8131 5956 99 www thorlabs de Email europe thorl...

Страница 19: ...www thorlabs com...

Отзывы: