THORLABS HVA200 Скачать руководство пользователя страница 14

High Voltage Amplifier 

18014-D02 Rev E, Sept. 3, 2019 

Page 14 

www.thorlabs.com 

Part 7.  Regulatory 

As required by the WEEE (Waste Electrical and Electronic Equipment Directive) of the 
European Community and the corresponding national laws, Thorlabs offers all end users 
in the EC the possibility to return “end of life” units without incurring disposal charges. 

This offer is valid for Thorlabs electrical and electronic equipment:

Sold after August 13, 2005

Marked  correspondingly  with  the  crossed  out
“wheelie bin” logo (see right)

Sold to a company or institute within the EC

Currently owned by a company or institute within the
EC

Still 

complete, 

not 

disassembled 

and 

not

contaminated

As  the  WEEE  directive  applies  to  self  contained  operational 
electrical  and  electronic  products,  this  end  of  life  take  back 
service does not refer to other Thorlabs products, such as: 

Pure OEM products, that means assemblies to be built into a unit by the user (e.g.
OEM laser driver cards)

Components

Mechanics and optics

Left over parts of units disassembled by the user (PCB’s, housings etc.).

If you wish to return a Thorlabs unit for waste recovery, please contact Thorlabs or your 
nearest dealer for further information. 

7.1. 

Waste Treatment is Your Own Responsibility 

If  you  do  not  return  an  “end of  life”  unit  to  Thorlabs,  you  must  hand  it  to  a  company 
specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste 
disposal site. 

7.2. 

Ecological Background 

It is well known that WEEE pollutes the environment by releasing toxic products during 
decomposition. The aim of the European RoHS directive is to reduce the content of toxic 
substances in electronic products in the future. 

The  intent  of  the  WEEE  directive  is  to  enforce  the  recycling  of  WEEE.  A  controlled 
recycling of end of live products will thereby avoid negative impacts on the environment. 

Wheelie Bin Logo 

Содержание HVA200

Страница 1: ...HVA200 High Voltage Amplifier Operating Manual ...

Страница 2: ... Product Overview 4 Part 3 Setup and Operation 5 3 1 HVA200 Controls and Features 7 3 2 Computer Controlled Operation 8 Part 4 HVA200 Specifications 10 Part 5 Maintenance 12 5 1 Fuse Replacement 12 5 2 Ventilation 12 5 3 Troubleshooting 12 Part 6 Declaration of Conformity 13 Part 7 Regulatory 14 Part 8 Thorlabs Worldwide Contacts 15 ...

Страница 3: ...ercise preventative safety measures to prevent contact between these high voltages and any personnel Warning The line switch and fuse must be set to the correct mains voltage The unit is shipped ready to operate on 115 V To operate on 230 V the line switch and fuse must be changed See Section 5 1 Fuse Replacement Do Not Open Housing The HVA200 has no user serviceable parts Service should only be p...

Страница 4: ...put amplifier includes a summing junction which allows an adjustable DC bias to be added to the input modulation This composite signal is then boosted by a fixed voltage gain of 20 by the output amplifier For added safety a front panel HV Enable button must be pressed to connect the HV output to the output BNC The output is automatically disabled each time the HVA200 is powered on The DC Bias cont...

Страница 5: ...to the HV Output connector 6 on the front panel HV Output Warning The HV output is capable of producing hazardous voltages and currents The HV output will handle an accidental short circuit without damage but the output should not be shorted continuously The current is internally limited to 100 mA 3 Optional Connect the HV monitor 4 to an oscilloscope or volt meter The input impedance must be at l...

Страница 6: ...his point the amplifier is powered up but the HV Output is disabled The power indicator should be illuminated If not check the AC fuse see page 12 Confirm that the HV Enable LED 5 is off 6 After confirming that all connections are correct the amplifier output can be enabled by pressing the HV Enable button on the front panel 5 7 Adjust the amplitude of the modulation signal as needed 8 The DC leve...

Страница 7: ...High Voltage Amplifier 18014 D02 Rev E Sept 3 2019 Page 7 www thorlabs com 3 1 HVA200 Controls and Features Figure 1 HVA200 Front Panel Features Figure 2 HVA200 Rear Panel Features 1 2 3 4 5 8 10 7 9 6 ...

Страница 8: ...nd prompt The basic structure of the interface is a keyword followed by either an equals sign or a question mark The or will determine if the string is a command or a query All strings commands and queries must be terminated by a carriage return CR or pressing the ENTER key on the computer The command structure is as follows Keyword argument CR Where keyword defines the function and argument is a ...

Страница 9: ... 0 Output is disabled enable 1 Output is enabled Get Output Enable enable Returns current output enable state Set Output Value value Sets Output value based on 16 bit number Get output Value value Returns set Output value Notes All commands and queries are in lower case letters value adjustment range based on 16 bit from 0 65535 0 maximum value 65535 minimum value To accurately set the output volt...

Страница 10: ...rature Range 10 to 40 C Max 85 RH Physical Features Input Connector BNC 10 V 10 mA HV Output Connector2 BNC 200 V 100 mA HV Monitor Connector3 BNC 10 V 200 mA Min Load 50 Ω Bias Adjustment Digital Encoder Output Enable Front Panel Pushbutton Output HV Indicator Bright LED Power Switch Rocker Switch Dimensions 9 x 5 x 12 5 228 6 mm x 127 mm x 317 5 mm Weight 11 6 lbs Other Tilting Rubber Padded Fee...

Страница 11: ... E Sept 3 2019 Page 11 www thorlabs com Figure 3 Typical Gain Bandwidth 16 18 20 22 24 26 28 1 0E 01 1 0E 02 1 0E 03 1 0E 04 1 0E 05 1 0E 06 1 0E 07 Voltage Gain dB Frequency Hz Typical Gain Bandwidth 20 Vpp Input 10 Vpp Input 1 Vpp Input ...

Страница 12: ...se compartment drawer out to expose the fuse A small screwdriver may be used to pry the drawer open Replace the fuse with the correct rating Do not use a fuse with a current rating higher than the unit is rated for The fuse ratings are as follows 115 V 630 mA 5x20 mm SLO BLO 230 V 400 mA 5x20 mm SLO BLO 5 2 Ventilation For proper operation and protection of the output amplifier it is important tha...

Страница 13: ...High Voltage Amplifier 18014 D02 Rev E Sept 3 2019 Page 13 www thorlabs com Part 6 Declaration of Conformity ...

Страница 14: ...orlabs products such as Pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards Components Mechanics and optics Left over parts of units disassembled by the user PCB s housings etc If you wish to return a Thorlabs unit for waste recovery please contact Thorlabs or your nearest dealer for further information 7 1 Waste Treatment is Your Own Responsibili...

Страница 15: ...anada and South America Thorlabs Inc sales thorlabs com techsupport thorlabs com Europe Thorlabs GmbH europe thorlabs com France Thorlabs SAS sales fr thorlabs com Japan Thorlabs Japan Inc sales thorlabs jp UK and Ireland Thorlabs Ltd sales uk thorlabs com techsupport uk thorlabs com Scandinavia Thorlabs Sweden AB scandinavia thorlabs com Brazil Thorlabs Vendas de Fotônicos Ltda brasil thorlabs co...

Страница 16: ...www thorlabs com ...

Отзывы: