background image

 

 

Introduction 

 

 

We are confident that you will be delighted with your Thor Gas Griddle, and it will become a most valued 
appliance in your commercial kitchen. 

To ensure you receive the utmost benefit from your new Gas Griddle, there are two important things you 
can do. 

 

Firstly:

 

 

Please read the instruction book carefully and follow the directions given.  The time taken will be well 
spent. 

 

Secondly:

 

 

If you are unsure of any aspect of the installation, instructions or performance of your appliance, 
contact your dealer promptly.  In many cases a phone call could answer your question. 

 

CE Only:

 

 

These instructions are only valid if the country code appears on the appliance.  If the code does not 
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for 
adapting the appliance to the conditions for use in that country. 

 

 

 

 

WARNING:

 

 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY 
DAMAGE, INJURY OR DEATH. 

 

READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR 
SERVICING THIS APPLIANCE. 

 

 

 

 

WARNING:

 

 

INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT 
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER. 

 

 

 

WARNING:

 

 

GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF 
FIRE. 
• 

THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED. 

• 

IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO 

ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED. 

• 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS 

OR ANY OTHER APPLIANCE. 

• 

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. 

 

 

 

CAUTION

 

THIS APPLIANCE IS; 

• 

FOR PROFESSIONAL USE AND IS TO BE USED BY QUALIFIED PERSONS ONLY. 

• 

ONLY QUALIFIED SERVICE PERSONS ARE TO CARRY OUT INSTALLATION, SERVICING AND GAS CONVERSION 

OPERATIONS. 

• 

COMPONENTS HAVING ADJUSTMENTS PROTECTED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY 

THE USER/OPERATOR. 

• 

DO NOT OPERATE THE APPLIANCE WITHOUT THE LEGS SUPPLIED FITTED. 

Содержание TR-G15F

Страница 1: ...vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or deat...

Страница 2: ...lation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 8 Operation Guide Lighting the Main Burner Cleaning and Maintenance 12 Routine Maintenance After Each...

Страница 3: ...ATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE...

Страница 4: ...Natural Gas Propane TR G15F TR G15F Single burner Heat Input 32 5 MJ 32 5 MJ Heat Total 32 5 MJ 32 5 MJ Burner Operating 1 0kPa 2 75kPa Supply Pressure 1 0kPa 2 75kPa Gas Connection BSP BSP The burne...

Страница 5: ...4 Dimensions TR G15F...

Страница 6: ...djusted by an authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic...

Страница 7: ...eing installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Gas supply requirements section of this manual Check the gas su...

Страница 8: ...specified in the Operation section of this manual Light the Pilot Burner Light the Main Burner Turning Off the Main Burner Pilot b Ensure that the operator has been instructed in the areas of correct...

Страница 9: ...T SEALED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY THE USER OPERATOR 1 The Gas Griddles have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is ther...

Страница 10: ...manually light the pilot burner or use the piezo igniter provided optional 3 Release the gas control knob after approximately 10 20 seconds after lighting the pilot burner 4 The pilot burner should s...

Страница 11: ...reate air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a su...

Страница 12: ...irror like surface OPERATION Turn the burners on about 15 20 minutes before cooking for preheating Set the knobs to the desired flame height or temperature Each valve will control the gas flow to the...

Страница 13: ...and prevents damage to the griddle plate surface INITIAL CLEANING Prior to operating your new griddle thoroughly wash the griddle surface and the exterior with a mild detergent or soap solution Do not...

Страница 14: ...a qualified service person To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service pe...

Страница 15: ...ified service person TOUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Pilot burner cannot be lit The pilot valve is obstructed Pilot gas turned off pilot valve The pilot valve is bad Fat appears to smoke e...

Страница 16: ...ntact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by...

Страница 17: ...16 Explosion drawing TR G15F...

Страница 18: ...G 01 20 1068637 7 U Burner TR G15F 06 05 1470384 1 8 Griddle Plate Assy TR G15F 06 05 1472746 1 9 Flue Assy TR G15F 06 05 1472727 1 10 L Connector For Manifold TR G15F 01 02 1005351 1 11 Regulator TR...

Страница 19: ......

Страница 20: ...Please keep this manual in a safe place for future use 15 Badgally Road Campbelltown NSW 2560 Thor after sales service 1300 225 960 V1 Rev2 08 18...

Отзывы: