WARNING

Do not combine the 12V model with 24V battery or the unit will 

be destroyed immediately. 
Operate with the inverter without a proper ground connection 

may cause an electrical safety hazard. 
Damage caused by reversed polarity is not covered by the 

warranty. Ensure the power switch is in the OFF position 

before putting the battery in. 

3-3. AC Safety Grounding

During AC wiring installation, AC input and output ground wires are 

connected to the inverter.  The AC input ground wire must be connected to

the incoming ground from AC utility source. 

The AC output ground wire should go to the grounding point for your loads 

( for example, a distribution panel ground bus ). 

3-3-1. Neutral Grounding (GFCI’S): 

110V models

The neutral conductor of the AC output circuit of the 

Inverter is automatically connected to the safety ground during inverter 

operation. This conforms to National Electrical Code requirements that 

separately derived from AC sources (such as inverters and generators) 

which have their neutral conductors tied to ground in the same way as 

the neutral conductors from the utility tied to ground at the AC breaker 

panel.  For models configured with a transfer relay, while AC utility 

power is present and the Inverter is in bypass mode, this connection 

(the neutral of the Inverter’s AC output to input safety ground) is not 

present so that the utility neutral is only connected to ground at your 

breaker panel, as required. 

Thor Mftg. 

has tested the following GFCI-

properly when connected to the output of the Inverter. 

WARNING

Never connect the inverter’s output to the AC distribution grid, 

such as the household AC wall outlet. 
It will damage the Inverter. 

7

Содержание THPS-150 Series

Страница 1: ...THPS 150 THPS 300 Series Pure Sine Wave Inverter User s Manual...

Страница 2: ...cal Performance 300W 3 2 3 Mechanical Drawing 150W 4 2 4 Mechanical Drawing 300W 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 6 3 3 AC Safety Grounding 7 3 4 Installation 8...

Страница 3: ...do not put batteries flammable materials or anything should be ignition protected around the inverter 1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts your skin or clothing...

Страница 4: ...wer Factor Allowed cos 90 cos 90 Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Remote Control Yes On Off controlled by external switch Safety Certif...

Страница 5: ...actor Allowed cos 90 cos 90 Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Remote Control Yes On Off controlled by external switch Safety Certificati...

Страница 6: ...150W AC OUTPUT POWER STATUS REVERSE POLARITY WILL DAMAGE UNIT DC INPUT USE FEMALE ANDERSON PP75 CONNECTOR ONLY CHASSIS GROUND POS NEG REMO ON OFF WARNING POWER 105 4 13 188 7 40 41 5 1 63 PURE SINE W...

Страница 7: ...2 4 Mechanical Drawing 5 Pure Sine Wave Inverter REMO ON OFF AC OUTPUT REMOTE PORT POWER STATUS 300W PURE SINE WAVE INVERTER...

Страница 8: ...stallation 3 1 2 LED display indicates Power Status LED Conditions Status Solid Green AC Power OK Fast Red Blink OVP Slow Red Blink UVP Intermittently Red Blink OTP Solid Red OLP 3 1 3 Remote Port Pla...

Страница 9: ...or of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation This conforms to National Electrical Code requirements that separately derived fro...

Страница 10: ...ents are checked OK and satisfied and all connections are made it s time to turn on the inverter by switching the power to I position The sine wave filters provide sine wave output voltage when driven...

Страница 11: ...available CIGARETTE CLAMP STRIPPED WIRE POWER CLAW PP45 3 6 AC output Outlet Sockets available Australia New Zealand IEC 2 Universal HARD WIRE United Kingdom North America GFCI IEC 1 NEMA 5 15R NEMA 5...

Страница 12: ...st be OFF 3 7 2 Before using the remote unit make sure the main switch must be REMOTE 3 7 3 Ensure the remote control contact is off 3 7 4 Remote Port Place 0 75mm2 and Screw type cable between the re...

Страница 13: ...ast Over input voltage Check input voltage Reduce input voltage b Power status light is blinking red slowly Low input voltage Recharge battery Check connections and cable c Power status light is blink...

Страница 14: ...fects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us with postage paid Pl...

Страница 15: ...Thor Manufacturing Inc 7050 W Palmetto Park Rd Suite 15 Boca Raton FL 33433 Toll free phone 1 866 955 THOR 8467 Web http www thorpowerproducts com...

Отзывы: