background image

Specification

Model No. 

Item

                         

  THPS-1000-12    THPS-1000-24      THPS-1000-48    THPS-1000-212  THPS-1000-224   THPS-1000-248

 

W

0

0

0

1

 

r

e

w

o

P

 

t

u

p

t

u

O

 

s

u

o

u

n

i

t

n

o

C

 

W

0

0

1

1

 

 

r

e

w

o

P

 

t

u

p

t

u

O

 

m

u

m

i

x

a

M

 

W

0

0

0

2

 

 

)

x

a

M

(

 

g

n

i

t

a

R

 

e

g

r

u

S

Input voltage 

12V 

24V 

48V 

12V 

24V 

48V 

Output Voltage 

100 / 110 / 120V     +/- 5% 

220 / 230 / 240V     +/- 3% 

Frequency 

(Switch Selectable) 

50 / 60Hz     +/-  0.05% 

 

)

 

%

3

 

<

 

D

H

T

 

(

 

 

e

v

a

W

 

e

n

i

S

 

e

r

u

P

 

m

r

o

f

e

v

a

W

 

t

u

p

t

u

O

Efficiency (full load) Max. 

*1

89.0% 

92.0% 

93.0% 

91.0% 

94.0% 

95.0% 

No Load Current Draw (Max.) 

1.43A 

0.75A 

0.38A 

1.25A 

0.65A 

0.35A 

Stand-By Current Draw (Max.) 

0.25A 

0.15A 

0.09A 

0.25A 

0.15A 

0.09A 

Input Voltage Regulation 

10.5-15

VDC

21.0-30

VDC

42-60

VDC

10.5-15

VDC

21.0-30

VDC

42-60

VDC

Input Level Indicator 

Red / Orange / Green     LED 

Load Level Indicator 

 

D

E

L

 

d

e

R

 

r

o

t

a

c

i

d

n

I

 

e

r

u

l

i

a

F

Protection 

Overload, Short Circuit, Reverse Polarity (Fuse),  

Over / Under Input Voltage, Over Temperature. 

Remote Control Units                                            TH-R6 / TH-R8  Optional

 

1

-

0

5

9

0

6

N

E

 

8

5

4

L

U

 

n

o

i

t

a

c

i

f

i

t

r

e

C

 

y

t

e

f

a

S

 

A

 

s

s

a

l

C

 

C

C

F

 

 

 

C

M

E

EN55022:   1997 
EN55024:   1997 
EN61000-3-2: 1998 
EN61000-3-3: 1995 

e-mark

e13 022694

Operating Temperature Range 

0 - 40 

Storage Temperature Range 

-30

 to 70

 

 

n

a

f

 

g

n

i

l

o

o

c

 

d

e

l

l

o

r

t

n

o

c

 

g

n

i

d

a

o

L

 

 

g

n

i

l

o

o

C

Dimensions 

340(L)*182(W)*88(H)mm / 13.39(L)*7.17(W)*3.46(H) Inch 

 

.

s

b

L

 

8

.

8

 

 

/

 

 

g

k

 

4

 

t

h

g

i

e

W

Note: The specifications are subject to change without notice.

Содержание THPS 1000 Series

Страница 1: ...THPS 1000 2000 3000 Series Pure Sine Wave Inverter User s Manual...

Страница 2: ...ition protected around the inverter 1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts skin or clothing you shall wash it out with soap and water immediately If battery acid co...

Страница 3: ...Input over voltage Over temperature 2 1 Application 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors etc 2 1 2 Office equipment computers printe...

Страница 4: ...15A 0 09A Input Voltage Regulation 10 5 15 VDC 21 0 30 VDC 42 60 VDC 10 5 15 VDC 21 0 30 VDC 42 60 VDC Input Level Indicator Red Orange Green LED Load Level Indicator D E L d e R r o t a c i d n I e r...

Страница 5: ...A 0 15A 0 60A 0 25A 0 15A Input Voltage Regulation 10 5 15 VDC 21 0 30 VDC 42 60 VDC 10 5 15 VDC 21 0 30 VDC 42 60 VDC Input Level Indicator Red Orange Green LED Load Level Indicator D E L d e R r o t...

Страница 6: ...e Regulation 10 5 15 VDC 21 0 30 VDC 42 60 VDC 10 5 15 VDC 21 0 30 VDC 42 60 VDC Input Level Indicator Red Orange Green LED Load Level Indicator D E L d e R r o t a c i d n I e r u l i a F Protection...

Страница 7: ...1 71 196 00 7 72 THPS1000 88 00 3 46 THPS1000 182 00 7 17 THPS1000 154 00 6 06 S3 S2 PWR S AV I O S1 LOAD LEVEL INPUT LEVEL S4 ST A TU S FREQ 10 00 W Pure Sine Wave Power Inverter POS NEG DC INPUT REV...

Страница 8: ...PS 2000 368 00 14 49 THPS3000 398 00 15 67 Pure Sine Wave Power Inverter 166 00 6 53 209 00 8 23 AC OUTPUT PURE SINE WAVE INVERTER S4 FREQ S2 S1 S3 PWR SAV O I 0 REMO LOAD LEVEL STATUS INPUT LEVEL OFF...

Страница 9: ...Panel Operations 3 1 1 Front view PURE SINE WAVE INVERTER AC OUTPUT OFF REMOTE I 0 ON S1 PWR SAV O I INPUT LEVEL FREQ STATUS S4 LOAD LEVEL S2 S3 THPS 1000 0 S4 S3 S1 S2 O THPS 2000 FREQ PWR SAV LOAD...

Страница 10: ...6 48 1 56 3 ORANGE Blink 14 2 15 0 28 6 30 0 56 3 59 6 OVER RED Blink 15 0 30 0 59 6 3 1 4 Load Level Display AC Loads Watts LED status DARK GREEN ORANGE RED RED BLINK THPS 1000 80W 80 330W 330 750W 7...

Страница 11: ...g Mode Power Saving Mode is adjustable and set by the Dip Switches S1 S2 and S3 on the front panel Example With the watt setting at 15W a 15W load will make the inverter operate normally a 15W load wi...

Страница 12: ...3 1 8 AC outlets available Australia New Zealand IEC 2 Universal HARD WIRE United Kingldom IEC 1 North America GFCI NEMA 5 15R NEMA 5 20R Continental European...

Страница 13: ...osition and the input voltage of the power inverter is the same as it of the remote unit 3 2 2 Fan Ventilation Be sure to keep it a distance at least 1 inch form surrounding things THPS 2000 THPS 3000...

Страница 14: ...0 48 V 42 0 60 0 3 2 4 Use wire 8 AWG to connect Chassis ground with vehicle chassis 3 3 Protections Features Model DC Input VDC Over Temperature Protection Over Voltage Under Voltage Alarm Under Volt...

Страница 15: ...om of the unit are not obstructed 3 4 5 Dust Do not install the Inverter in a dusty environments The dust can be inhaled into the unit when the cooling fan is working 3 4 6 Close to batteries Avoid ex...

Страница 16: ...or surge capability and frequent low input voltage warnings and shutdowns These low input voltage warnings are due to DC voltage drop across the cables from the inverter to the batteries The longer an...

Страница 17: ...rt a maximum of 3 6 feet WARNING The installation of a fuse must be on a positive cable Failure to place a fuse on cables running between the inverter and battery may cause damage to the inverter and...

Страница 18: ...AZARD DO NOT OPEN NO USER SERVICEABLE PARTS INSIDE WARNING DC INPUT POS CHASSIS GROUND NEG REMOTE PORT Battery to inverter cable connection Do not place anything between battery cable lug and terminal...

Страница 19: ...nt and the Inverter is in bypass mode this connection the neutral of the Inverter s AC output to input safety ground is not present so that the utility neutral is only connected to ground at your brea...

Страница 20: ...n the inverter will make self diagnosis and the LED s indicators will also appear various colors Finally the buzzer will Beep again and the Input Level and Status LED indicators will turn to Green col...

Страница 21: ...rge battery Check connections and the cable c Blinking Intermittently Thermal shutdown OTP Improve ventilation Make sure ventilation shafts in the inverter are not obstructed Lower ambient temperature...

Страница 22: ...g properly there is very little maintenance required You should clean the exterior periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC...

Отзывы: