background image

 

E2

E5

E6

Prompt and Alarm Information

  In case of an improper operation or trouble with the machine when it 
operates, the code corresponding to the trouble will be displayed on the 
screen:

Code

Category

Cause

Solutions

Trouble code

Trouble code

Trouble code

There is no change in
 the temperatures of
 the laundry in the tub

Contact a professional 
       serviceman

The thermal sensor 
open-circuited or short 
circuited

Contact a professional 
       serviceman

Drain pump fails

Contact a professional 
        serviceman 

Trouble Shooting

Trouble Shooting

Содержание THOR VL9000

Страница 1: ...er Program selector Container handle Name of Parts Door Front grill SAVE THESE INSTRUCTIONS Programming guide 14 Important Safety Instructions 2 3 Name of Parts 1 This diagram may be slightly different from the layout of the machine you have just purchased due to techincal improvements Read all instructions before using dryer Dryers are provided with operating care and in stallation instructions W...

Страница 2: ...g feathers or down 10 Do not place items exposed to cooking oils in your dryer Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire 11 Clean lint screen before or after each load 12 This dryer must be properly installed in accordance with the installation instructions before it is used 13 To prevent shock hazard and assure stability durin...

Страница 3: ...s there are signs of damage Contact your dryer supplier Ƶ The dryer must be kept away from flammable substances Ƶ The surrounding environment must be dry and ventilated Ƶ To allow the dryer to perform better the ambient temperature shall not be lower than 50 degree F nor higher than 95 degree F Change the door opening direction If the direction of the dryer s door is not suitable to the location i...

Страница 4: ...y grounded The dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Power Supply 3 or 4 wire 240 Volt 30 Amp 60Hz 1 Phase Power Supply Cord Kit not supplied when sold in the United States The dryer MUST employ a 3 conductor power supp...

Страница 5: ...bend or crimp wiring conductor at connections 7 Tighten the screws securing the cord restraint firmly against the power cord 8 Tighten the strain relief nut securely so that the strain relief does not turn 9 Install the terminal block cover supplied as an accessary together with two screws Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper opera...

Страница 6: ...ion Ƶ Before use clean any deposits from inside the drum of the dryer with a wet towel Ƶ Clean debris on the filter screen to increase the drying efficiency Warning Do not dry wool silk down and other delicate fabrics to avoid damage to fabrics Load to dry Make sure that the laundry you are going to dry is suitable for drying in a dryer You will find information on this on the laundry labels The f...

Страница 7: ...ernatively and the control panel will lock Press and hold down both buttons for 3 seconds once again and the child lock will release When the program is finished or the power is turned off during the program the child lock will release H LED screen The screen displays the remaining time for a program the delay time and other related information Note The remaining time to start a program is the def...

Страница 8: ...y End Open the door to remove the laundry If the laundry is not removed after the drying program is complete the dryer will start the anti crease protection cycle automatically In the anti crease protection cycle the dryer s drum will run at a set interval to keep your laundry loose 7 Turning off the dryer Press the power button to cut off the power supply 1 Turning on power Insert the power plug ...

Страница 9: ...It will not restart until the box is emptied Note The collection box does not need to be emptied if the drain option is installed 4 Cleaning the condenser The condenser must be cleaned monthly Switch off the power supply before cleaning Hold the protrusions on both sides of the lower panel and open it Using a coin or other tool push the slides on the cover to the position as shown in the figure an...

Страница 10: ... displayed on the screen Code Category Cause Solutions Trouble code Trouble code Trouble code There is no change in the temperatures of the laundry in the tub Contact a professional serviceman The thermal sensor open circuited or short circuited Contact a professional serviceman Drain pump fails Contact a professional serviceman Trouble Shooting Trouble Shooting ...

Страница 11: ...2 x24 3 8 x23 7 16 T Item Wiring Circuit Specifications PCB1 PCB2 P S M R1 R2 T1 T2 K1 NTC H K2 K3 L1 K3 L2 G PCB1 PCB2 P S K1 NTC H K2 K3 K3 R1 Heating1 R2 Heating2 T1 Non self restting thermal cut out T2 Thermostat K1 Door switch K2 Level switch K3 Power switch H Humidity sensor NTC Temperature sensor PS Drainage pump M Motor PCB1 PCB2 Printed circuit board ...