background image

7

Appliances such as microwave ovens will normally draw more than their rated current and could possibly overload 

the inverter when operated simultaneously with other appliances. For example: A 600 watt microwave oven draws 

approximately 940 watts.

Rechargeable Devices

 CAUTIONS

• Some rechargeable devices are designed to be charged by plugging them directly into an AC receptacle. These 

devices may damage the inverter or the charging circuit. 

• When using a rechargeable device with your inverter, monitor its temperature for the initial ten minutes of use to 

determine if it produces excessive heat. If excessive heat is produced, the device should not be used with your 

inverter. 

•  This problem does not occur with most battery-operated appliances and tools. Most of these appliances use a 

separate charger or transformer that is plugged into an AC receptacle. 

• Your inverter is capable of running most chargers and transformers.

 POWER SOURCE AND PROTECTIVE FEATURES

Power Source Requirements

Your inverter will operate from input voltages between 11 and 16 volts DC. If the voltage drops below 11 volts, an 

audible low battery warning alarm will sound. If the input voltage drops below 10 volts DC, the inverter will shut 

down. This feature protects the battery from being completely discharged.

The inverter will also shut down if the input voltage exceeds 16 volts. This protects the inverter against excessive 

input voltage. Although the inverter has built-in protection against over voltage, it may still be damaged if the input 

voltage exceeds 17 volts.

Your inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner 

described in the “Installation” section of this Instruction Manual. Do not connect the inverter to household or RV AC 

distribution wiring. Do not connect the inverter to any AC load circuit in which the neutral conductor is connected to 

ground (earth) or to the negative of the DC (battery) power source.

The inverter will operate most AC loads within its power rating. Some induction motors used in refrigerators, 

freezers, pumps and other motor-operated equipment, require very high surge currents to start them. The inverter 

may not be able to start some of these motors even though their rated current draw is within specifications for this 

power inverter. If a motor refuses to start, observe the battery voltage using a DC voltmeter while trying to start the 

motor. If the battery voltmeter drops below 11 volts while the inverter is attempting to start the motor, this may be 

why the motor won’t start. Make sure the battery connections are tight and the battery (or batteries) is (are) fully-

charged. If the connections are good and the battery is charged, but the voltage still drops below 11 volts, you may 

need to use a larger battery (or battery combination).

Inductive loads, such as TVs and stereos, require more current to operate than resistive loads of the same wattage 

rating. Induction motors, as well as some TVs, may require two to six times their rated wattage to start up. Because 

these inverters have a peak watt power rating, many such appliances and tools may be safely operated. The 

equipment that needs the highest starting wattage are pumps and compressors that start under load. This 

equipment can be safely tested. If an overload is detected, the inverter will simply shut down until the overload 

situation is corrected. 

 CAUTIONS

• Exceeding recommended voltage limits will void manufacturer’s warranty.

• NEVER try to use your inverter with any 12 volt DC power source that uses a positive ground. (Most vehicles and 

boats use negative ground systems.)

• The Power Inverter must be connected only to batteries with a nominal output voltage of 12 volts. The unit will not 

operate from a 6 volt battery and will sustain permanent damage if connected to a 24 volt battery.

• Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter.

Содержание PPI Series

Страница 1: ...ING This product contains chemicals known to the State of California to cause cancer and or reproductive harm birth defects or other reproductive harm ADVERTENCIA Este producto contiene productos quimicos reconocidos por el estado de California que provocan cáncer o daños reproductivo defectos de nacimineto u otros daños reproductivos ...

Страница 2: ...ht 2018 THOR Manufacturing Please register your product at www thorpowerproducts com In NO event shall THOR Manufacturing be liable for indirect special or consequential damages Instruction Manual and Warranty Information PPI Series Portable Power Inverter THMS 500 PPI THMS 800 PPI ...

Страница 3: ...y hazardous situation which if not avoided may result in property damage RISK OF UNSAFE OPERATION When using tools or equipment basic safety precautions should always be followed to reduce the risk of personal injury Improper operation maintenance or modification of tools or equipment could result in serious injury and property damage There are certain applications for which tools and equipment ar...

Страница 4: ...BATTERY MANUFACTURER AND THE MANUFACTURER OF ANY EQUIPMENT YOU INTEND TO USE WITH THIS UNIT REVIEW CAUTIONARY MARKINGS ON THESE PRODUCTS AND ON ENGINE TABLE OF CONTENTS Introduction 4 Features 4 Controls and Functions 4 How These inverters work 5 Power Inverter Output Waveform 5 Appliance Power Consumption 6 Rechargeable Devices 7 Power Source and Protective Features 7 Power Source Requirements 7 ...

Страница 5: ...arately This also displays inverter fault codes if the inverter happens to shut down from over load or over temperature condition or abnormal input voltages The ON OFF Switch turns the inverter ON and OFF The switch can also be used to force reset of inverter circuits by switching it OFF then back ON again All models also feature a port to attach a remote control sold separately 120 volt AC power ...

Страница 6: ...s The modified sine wave produced by this inverter has an RMS root mean square voltage of 115 volts Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave These meters will not correctly read the RMS voltage of a modified sine...

Страница 7: ...r example if a load is rated at 200 wattsAC the power source must be able to deliver 200 divided by 10 20 amperes Your inverter will operate most AC loads within its power rating Some induction motors used in refrigerators freezers pumps and other motor operated equipment require very high surge currents to start them Your inverter may not be able to start some of these motors even though their ra...

Страница 8: ...neutral conductor is connected to ground earth or to the negative of the DC battery power source The inverter will operate most AC loads within its power rating Some induction motors used in refrigerators freezers pumps and other motor operated equipment require very high surge currents to start them The inverter may not be able to start some of these motors even though their rated current draw is...

Страница 9: ...s conditions Low Battery Voltage This condition is not harmful to the inverter but could damage the power source An alarm will sound when input voltage drops below 10 5 volts and the inverter will automatically shut down when input voltage drops below 10 0 volts This indicates that the DC battery power source needs to be charged or there is an excessive voltage drop between the battery power sourc...

Страница 10: ...ting wiring that has been approved for marine use at the appropriate gauge cable and length The cable fuse holder and fuse not supplied can be purchased at an electrical supply company Call the manufacturer for additional installation information Quick Operational Test or Emergency Use You will need A heavy duty jumper cable set of the specified AWG wire rating refer to the Installations section o...

Страница 11: ...iminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions Permanent Installation Procedure IMPORTANT Please follow installation and wiring instructions exactly as outlined to ensure safety We recommend installation by an RV technician or professional electrician to ensure adherence to relevant electrical ...

Страница 12: ...grounded At no point should the chassis ground and the neutral conductor of the inverter be bonded Bonding the chassis ground and the neutral conductor of the inverter or connecting the inverter to household or recreational AC distribution wiring will damage the unit and void the warranty CAUTION This inverter cannot supply power to any AC distribution wiring or AC loads in which the neutral and g...

Страница 13: ...e space for proper ventilation of the inverter 2 Press the Power Pushbutton to turn the unit ON 3 The display will light up indicating a proper connection If the display displays a fault code indicating a fault condition exists refer to the Troubleshooting section of this Instruction Manual 4 Plug the USB powered device into the inverter s USB Charging Port and operate normally Note This unit s US...

Страница 14: ...OLTAJE Voltaje de la batería es demasiado alto Compruebe si hay fallas en el sistema de carga de la batería OVERLOAD SHUTDOWN Excessive start up load Power tool or appliance draws too much voltage and cannot be used with your inverter Inadequate power being delivered to the inverter or excessive voltage drop Use heavier Gauge wire See Installation Specifications in users manual APAGADO DE SOBRECAR...

Страница 15: ...Chargers AC terminal block connections Check the ground connections are secure on the Inverter Charger Battery Bank Main Sub Panels and the Earth Ground on the RV Boat ACCESSORIES If you need assistance regarding accessories please call 1 866 955 THOR or visit www thorpowerproducts com WARNING The use of any accessory not recommended for use with this tool could be hazardous and will void manufact...

Страница 16: ...ms or items that are not under warranty or units that are not defective will be charged a minimum bench charge of 50 00 US plus taxes and shipping A 15 restocking charge will be applied on goods returned and accepted as new stock An RMA number Return Materials Authorization number from THOR Manufacturing s Customer Service is required prior to returning any THOR Manufacturing products THOR Manufac...

Страница 17: ...C Input Connections Conexion De Entrada VCD Twist Down Input Lugs Atornille Agarraderas De Entrada Twist Down Input Lugs Atornille Agarraderas De Entrada Ac Output Connections Conexcion De Salida No De Recipientes Nemas 15R 2 2 Remote Control Connection Puerto De Control Remoto Yes Si Yes Si Remote Control Optional Control Remoto 20 Foot Remote Control Control Remoto Con Cable 20 Pies 20 foot remo...

Страница 18: ...n building replacement products THOR Manufacturing reserves the right to use parts or products of original or improved design in the repair or replacement If THOR Manufacturing repairs or replaces a product its warranty continues for the remaining portion of the original warranty period or 90 days from the date of the return shipment to the customer whichever period expires later All replaced prod...

Отзывы: