THOR GH103-N Скачать руководство пользователя страница 19

Trouble shooting

 

17 

                 Fault

 

Possible  Cause

 

Remedy

 

 

Pilot won’t light.

 

No gas supply or gas isolation 

valve is OFF.

 

Ensure gas isolation valve is turned on, 

and that gas tanks are not empty.

 

Pilot burner is clogged/blocked.  Check the pilot burner if clogged, and 

clean, or replace if necessary. Follow 

the FDS removal procedure. 

ODS injector is clogged. 

Check the ODS injector if clogged, and 

clean if necessary.  Follow the ODS 

injector removal procedure. 

ODS injector is damaged. 

Check if the ODS injector is 

blocked/damaged, and replace it if 

necessary.  Follow the ODS injector 

removal  procedure. 

 

Pilot goes out when gas 

control knob released.

 

Releasing the knob 

before the 

thermocouple has 

heated.

 

Hold the knob in for at least 10~20 

seconds following ignition of the 

pilot.

 

Gas pressure too low.

 

Check the pressure of the main line if 

within standard.  Adjust the pressure if 

necessary.  

NG – 1.0KPa and LPG – 2.75KPa. 

Partially blocked ODS injector. 

Clean the ODS injector or replace the 

ODS injector if necessary.  Follow the 

ODS injector removal procedure.

 

Thermocouple connection to 

the safety gas valve is loose. 

Tighten the thermocouple 

connection. 

Faulty thermocouple or ODS.

 

Replace the thermocouple or ODS.  
Follow the thermocouple removal 

procedure. 

Faulty safety gas valve.

 

Replace the safety gas valve.  Follow 

the safety gas valve removal procedure.

 

PILOT TROUBLE SHOOTING 

CHECKING & CLEANING OF THE ODS INJECTOR: 

1. Visually check the orifice of the pilot injector 

if clogged, damaged or blocked.   If it cannot 
be  checked  visually,  try  to  blow    air  in  the 
injector and check if there is air coming out 
of the orifice. 

2. If the orifice is blocked or clogged, use an air 

blow  to  remove  the  clogging.    Never  pinch 
the  orifice  with  a  pin  as  this  could  damage 
the orifice. 

3. If the clogging cannot be removed from the 

orifice by air blow, replace the injector with 
a new one.  Remember to check the size of 
the orifice and replace with the same size. 

4. Follow the ODS injector removal procedure. 

FLAME DEVICE SYSTEM 

PILOT 

BURNER 

THERMO

COUPLE 

IGNITER 

ROD 

ODS 

INJECTOR 

ODS INJECTOR 

ORIFICE 

NOTE:

      When  you  order  a  Flame  Device  System 

(FDS),  the  ODS  injector  is  not  included.    The  ODS 
injector can be ordered separately. 

Содержание GH103-N

Страница 1: ...e vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause pro...

Страница 2: ...mensions 3 Installation 4 6 Operation 7 10 Cleaning and Maintenance 11 12 Troubleshooting 13 25 Conversion from NG to LPG and vice versa 24 Explosion Drawing ALL PARTS 26 Parts List ALL PARTS 27 28 Ex...

Страница 3: ...OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE...

Страница 4: ...at the gas control valve outlet test point with one burner operating at High setting The operating pressure is ex factory set through the appliance regulator and not to be adjusted Minimum input Heat...

Страница 5: ...Dimensions GH103 P GH103 N 3 GH104 P GH104 N...

Страница 6: ...n authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic coating from...

Страница 7: ...ply to ensure adequate supply pressure exists c Input Rate of this appliance is stated on the Rating label The input rate should be checked against the available gas supply line capacity Particular no...

Страница 8: ...ration section of this manual Light the Pilot Burner Light the Main Burner Turning Off the Main Burner Pilot b Ensure that the operator has been instructed in the areas of correct lighting operation a...

Страница 9: ...ED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY THE USER OPERATOR 1 The Gas Char broilers have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is there...

Страница 10: ...manually light the pilot burner or use the piezo igniter provided optional 3 Release the gas control knob after approximately 10 20 seconds after lighting the pilot burner 4 The pilot burner should st...

Страница 11: ...reate air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a su...

Страница 12: ...lowest temperatures on the outside burners A uniform and systematic approach to the loading of the unit will produce the most consistent product results RADIANTS Place the radiants in their position M...

Страница 13: ...the grates may cause them to warp It will also cause damage to the valves the knobs and the front panel C Place grates on char broiler with grid bars horizontal facing down D Turn the char broiler on...

Страница 14: ...y from the control panel b Remove the drip tray from the appliance c Remove the four screws on the underside of the control panel securing the control panel to the hob d Remove the control panel from...

Страница 15: ...on when valve is turned on Pilot burner not lit Gas valve is bad Pilot burner will not light Obstructed pilot orifice Pilot valve turned off Pilot burner will not stay lit Obstructed pilot orifice Ga...

Страница 16: ...around an appliance may lower oxygen content in the surrounding air This can be a result of spillage of combustion products into the room as well These conditions can cause incomplete combustion and...

Страница 17: ...also causes its problems Yellow tipping is one of them Flames will eventually become all yellow if no primary air is supplied These yellow tips are caused by glowing carbon particles in the flame Soo...

Страница 18: ...al manner UNSTABLE OR WAVERING FLAMES Drafts across burners may cause flames to waver or appear to be unstable This condition should not be confused with lifting or floating flames Wavering burner fla...

Страница 19: ...ssary Follow the ODS injector removal procedure Thermocouple connection to the safety gas valve is loose Tighten the thermocouple connection Faulty thermocouple or ODS Replace the thermocouple or ODS...

Страница 20: ...R PILOT TUBE FITTING ODS INJECTOR FLAME DEVICE SYSTEM FDS REMOVAL 1 Turn off the pilot 2 Shut off the main isolation valve and follow the lock out tag out procedure 3 Remove the grills radiants or lav...

Страница 21: ...Make sure to check for gas leak using soap water after part installation Disconnect the thermocouple from the safety gas valve Remove the thermocouple lock nut SAFETY GAS VALVE THERMOCOUPLE THERMOCOUP...

Страница 22: ...low Safety gas valve low flame setting is not adjusted to desired flame height Adjust the low flame setting of the safety gas valve to your desired flame height Main burner flame color is yellow or or...

Страница 23: ...rn off the pilot 2 Shut off the main isolation valve and follow the lock out tag out procedure 3 Remove the knob control panel cover and piezo igniter connection 4 Remove the drip tray 5 Disconnect th...

Страница 24: ...the main pipe assy thermocouple and pilot tube assy from the safety gas valve 7 Remove the two mounting screws of the left injector fix plate 8 Remove the left main pipe assy and injector fix plate 9...

Страница 25: ...JUSTMENT KNOB BURNER AIR SUPPLY ADJUSTMENT 1 Turn off the pilot 2 Shut off the main isolation valve and follow the lock out tag out procedure 3 Remove the trivets 4 Remove the burner to be adjusted 5...

Страница 26: ...ner injector Follow the main burner injector removal procedure See table below for injector orifice size 9 Replace the pilot injector Follow the pilot injector removal procedure See table below for in...

Страница 27: ...ized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by description and quote mo...

Страница 28: ...Explosion drawing ALL PARTS 26 GH103 P GH103 N...

Страница 29: ...5 1471845 1 9 Main pipe assy left GH103 P GH103 N GH104 P GH104 N 06 05 1471982 1 10 Pilot pipe assy left GH103 P GH103 N GH104 P GH104 N 06 05 1471981 1 11 Heating insulation panel side GH103 P GH103...

Страница 30: ...26 Orifice GH103 P GH104 P 01 20 1068652 2 3 GH103 N GH104 N 01 20 1068637 2 3 27 Tray fix GH103 P GH103 N GH104 P GH104 N 01 05 1028915 2 2 28 L connector GH103 P GH103 N GH104 P GH104 N 01 18 10674...

Страница 31: ...Explosion drawing SPARE PARTS 29 GH103 P GH103 N...

Страница 32: ...1015048 4 6 10 U Burner GH103 P GH103 N GH104 P GH104 N 06 05 1470384 2 3 11 Flue Assembly GH103 P GH103 N GH104 P GH104 N 06 05 1471837 06 05 1471865 1 12 Flame Device System No include injector GH1...

Отзывы: