Dimension and Clearance
12
5.
Gas Supply Requirements
Installation of this range must conform with local codes, or in the absence of local codes, with
national Fuel Gas Code
,
ANSIZ223.1 / NFPA 54.
In Canada, installation must conform to the current natural Gas Installation /code, CAN 1-1.1-M81
and with local codes where applicable.
This range has been design-certified according to ANSIZ21.1a, latest edition.
Reading
LP in. w.c.
NG (Natural Gas)
in. w.c,
Maximum gas pressure
13.0.
10.0
Appliance Regulator Setting for outlet
pressure
10.0
5.0
Safety Tips for Gas Operation
✓
Keep appliance area clear and free from combustible materials, gasoline, and other
flammable vapors.
✓
Do not obstruct the flow of combustion air into the range and ventilation air away from the
range.
✓
Ventilation: it is a must that the unit be set under a powered, vented exhaust hood of
sufficient size and capacity.
✓
Before installing the range, you must locate and secure the included anti-tip bracket to the
wall for your range.
✓
The use of cabinets for storage above the appliance may result in a potential burn hazard.
Combustible items may ignite; metallic items may become hot and cause burns. If a cabinet
storage is to be provided, the risk can be reduced by installing a range hood that projects
horizontally a minimum of 5" (12.7cm) beyond the bottom of the cabinets.
Содержание LRG series
Страница 1: ...LRG PROFESSIONAL GAS RANGE...
Страница 15: ...DimensionandClearance 14 BTU Design...
Страница 16: ...DimensionandClearance 15...
Страница 17: ...DimensionandClearance 16 LRG3001U LRG3601U LRG4801U LRG4807U...
Страница 18: ...17 DimensionandClearance LRG3001U LRG3601U...
Страница 19: ...18 DimensionandClearance LRG4801U LRG4807U...
Страница 20: ...19 DimensionandClearance...
Страница 21: ...20 DimensionandClearance...
Страница 22: ...DimensionandClearance 20 48 Gas Range Clearance...
Страница 24: ...DimensionandClearance 22...
Страница 26: ...DimensionandClearance 24 LRG3601U LRG4801U...
Страница 27: ...DimensionandClearance 25 LRG4807U...