47
6.9 Defrost heater
Rated voltage:AC220-240V
Rated power:250W
6.9.1 Basic parameters
6.9.2 Checking method
6.Circuit and checking
1.Enter compulsory defrost mode,use a multimeter to measure
voltage between label N and label DEF HT on CN2 connector of the
mainboard,if the voltage doesn’t equal to electric supply power,it
means the heater is broken,change it.
2.Check the fuse is well or not,refer to “6.8 Temperature fuse”chapter.
3.Use a multimeter to measure resistance of the heater,if the value
isn’t 212
Ω±5%,
it is broken,change the heater.
Содержание HRF3603F
Страница 1: ...Model HRF3603F Refrigerator Service Manual ...
Страница 7: ...2 3 Evaporator structure 6 2 Appearance and structure Fuse Sensor Heater Evaporator ...
Страница 10: ...9 4 Operation and functions 4 1 Display controls 4 Operation and functions ...
Страница 11: ...10 4 Operation and functions 4 1 Display controls ...
Страница 12: ...11 4 Operation and functions 4 1 Display controls ...
Страница 15: ...14 4 4 Error display 4 Operation and functions 4 4 1 Error code ...
Страница 21: ...20 5 Troubleshooting 5 1 Common problem and checking ...
Страница 22: ...21 5 Troubleshooting ...
Страница 54: ...53 7 Refrigeration system repair 7 2 Summary of repair ...
Страница 55: ...54 7 3 Regualation for repair 7 Refrigeration system repair ...
Страница 56: ...55 7 4 Practical work for repair 7 Refrigeration system repair ...
Страница 57: ...56 7 4 Practical work for repair 7 Refrigeration system repair ...