TC807 C/CS
Updated 03 / 02
First issue 03 / 00
EAST-WEST MODULE
1 - PL140 : Turn fully counterclockwise.
MAIN BOARD
2 - Adjust Horizontal Centering (HS)
3 - Adjust Vertical centering (VSH) and Vertical amplitude 107% (VA)
4 - Adjust Vertical Slope (VS) and linearity (SC)
5 - If necessary repeat VSH, VA alignment to 7% overscan.
EAST-WEST MODULE
6 - PL140 : Adjust Horizontal amplitude with PL140 for optimum overscan.
7 - PL141 :Adjust Pincushion.
8 - PL143 : Adjust Trapezium
9 -If necessary repeat Horizontal amplitude, pincushion correction and
trapezium alignment
1 - Adjust Horizontal Centering (HS)
2 - Adjust Vertical centering (VSH) and Vertical amplitude 107% (VA)
3 - Adjust Vertical Slope (VS) and linearity (SC)
4-If necessary repeat VSH, VA alignment to 7% overscan.
GEOMETRY MODE ALIGNMENT
90° tube
Signal : 50 Hz - 4/3 test pattern
4 / 3
standard mode
Overscan V=107% , H=107%
110° tube
Signal : 50 Hz - 4/3 test pattern
4 / 3
standard mode
Overscan V=107% , H=107%
ALIGNMENT PROCEDURE - PROCESSUS DE REGLAGES - ABGLEICH -
VISUALIZZAZIONE DEL VALORE DI REGOLAZIONE - PROCEDIMIENTO DE ALINEACION