THOMSON DFT-6101 Скачать руководство пользователя страница 7

DFT-6101 Battery Resistance Tester Instruction Manual

 

     

     

 

Setting interface              Testing interface                          End interface 

 

2.2.1

 (Optional): Test instructions with connection resistors (same Test in Strings)

 

3-wire  &  3-clamp  simultaneous  Test.  The  red  clamp  is  connected  to  the  connection  resistor,  the  red  and  black 

clamp is connected to the end of the positive pole of the battery and the connection resistance, the black clamp is 

connected  to  the  negative  electrode  of  the  battery,  click  the  Test,  you  can  complete  the  Test  of  the  internal 

resistance and the connection resistance, and so on.   

(Note that in  general, the first section  of the positive  electrode of  the  electrical Test  does not have a connecting 

strip, you can connect the red clamp with the red and black clamp at the positive end of the battery, direct  Test, 

then the connection resistance value of the first section is 0) 

 

2.3. 

Battery String Test 

 

The Battery String Test interface is as follows, and its Test operation method is similar to that of single cell Test, 

but the number of battery cells is increased, and before a String of batteries is tested, it can be tested continuously 

without operating the interface. Click the touch screen Start Test button to take the Test. 

 

Содержание DFT-6101

Страница 1: ...DFT 6101 Battery Resistance Tester Users Manual THOMSON TECH CO LTD www thomsontesting com ...

Страница 2: ... selection 7 2 3 3 Operating instructions 7 2 4 Data management function 7 2 5 Clock settings 8 2 6 System Administration 8 2 6 1 File management 9 2 6 2 Language selection 9 2 6 3 Test the waveform 9 2 6 4 Software Version information 10 Chapter 3 Tester Main Parts Structure 11 3 1 Package List 11 3 2 DFT 6101 Host 11 3 3 Testing Line 12 3 4 Host Charger 12 3 5 Data Line 13 3 6 Box 13 Chapter 4 T...

Страница 3: ...nternal resistance matching when the new battery is matched Testing the internal resistance of the battery before and after discharging is used to identify the real invalid battery 1 2 Feature 1 Smart digital fully English operation menu for accurate Test simple operation 2 Weight does not exceed 0 45Kg handheld design single operation automatic Test of the whole process 3 To meet various battery ...

Страница 4: ...and the inside of the metal head is serrated to facilitate the removal of oxides and direct contact with the pole thus ensuring the stability and accuracy of the test results 1 4 Advantages of test probes 1 4 line test ensure that the inner needle is completely insulated from the outer barrel 2 Inner needle 1 3 mm diameter outer barrel 3 mm diameter are suitable for a variety of connection strip g...

Страница 5: ...uage selection test waveforms file management and software version information and other functions 1 6 Technical parameters Item parameters Measuring range resistance 0 0mΩ 120mΩ Voltage 0 000v 20v Tiebar Measuring range option 0 0mΩ 65 0mΩ Min Resolution resistance 0 001mΩ Voltage 1mV Test accuracy resistance 1 Voltage 0 5 Display 272 480 4 3 TFT LCD touch screen 272 480 Host Size 186mm 98mm 40mm...

Страница 6: ... name and on the right is the battery level indicator The bottom edge is the time bar and the middle is the display and operation area When using the touch screen you can tap the menu task item directly and then tap the selected menu task item to execute If you are using a keyboard use the TAB key to toggle the selected menu task item and press Confirm to execute 2 2 Single Cell Test After enterin...

Страница 7: ...the internal resistance and the connection resistance and so on Note that in general the first section of the positive electrode of the electrical Test does not have a connecting strip you can connect the red clamp with the red and black clamp at the positive end of the battery direct Test then the connection resistance value of the first section is 0 2 3 Battery String Test The Battery String Tes...

Страница 8: ...fter clicking the Save button at the bottom of the String Test interface the set parameters will be saved permanently and the switch will not be lost again and there is no need to set the parameters repeatedly which is convenient for the next test 2 3 3 Operating instructions Click the Operation Instructions button and the dialog window that pops up details the operation process and precautions of...

Страница 9: ...operate then the TAB key toggles the input items after selecting good years Month Day Hours Minutes Seconds press The key increments or decreases the number 2 6 System Administration Once you enter system settings the system settings submenu appears Click the task item to enter the system settings surface and click the back button to return to the main menu The menu content is shown in the followi...

Страница 10: ...tically starts to the running interface after the upgrade is successful 2 6 2 Language selection The software supports 5 languages of Chinese English French Spanish German the software needs to reserve a multi language switching mode The language selection interface refers follows In the language selection interface select the language you want to use click Confirm and then switch the display inte...

Страница 11: ...er Instruction Manual 10 2 6 4 Software Version information Double click the Version Info menu item under the system management menu page to view the teetered system software version and Tester series number S N as shown in the figure ...

Страница 12: ...ackage List Battery Resistance Tester DFT 6101 Host 1pc Test clamp or Probe 1kit Host Charger 1kit U disk 1pc Data line 1pc Box 1pc User manual 1pc Packing list 1pc 3 2 DFT 6101 Host The host is used for field testing by operation calculation test results display Storage and other use Quantity 1 unit ...

Страница 13: ...attery Resistance Tester Instruction Manual 12 3 3 Testing Line Testing Line is either or of Testing Line clamp or Testing Line probe 3 4 Host Charger Host Charger is for Host inside battery charging Quantity 1pc ...

Страница 14: ...DFT 6101 Battery Resistance Tester Instruction Manual 13 3 5 Data Line Data Line is for data communication from host to PC by U disk 3 6 Box Used to pack the main host and accessories Quantity 1pcs ...

Страница 15: ... Boot screen data Logpic BMP Length X width 272X480 2 Test result data File name AAACCCC DAT AAA is REM CCCCC is serial number Such as REM00035 DAT 4 3 Data management Under the Data Management function in the main menu of the gauge Data files can be opened export dump U disk Delete single piece of data format delete all data and so on The data file is transferred to a U disk in THE DAT file forma...

Страница 16: ...organized and placed in the appropriate position in the chassis In order to keep the battery in optimal condition it is recommended to charge the battery regularly once a month 5 3 Tester s Battery maintenance 1 Battery charging At the time of delivery the battery may not be charged and should be charged before use Power on to check the charging status if the battery voltage is too low to turn on ...

Страница 17: ...DFT 6101 Battery Resistance Tester Instruction Manual 16 Battery Data Management PC Software Manual THOMSON TECH CO LTD ...

Страница 18: ...8 1 1 Software runtime environment 18 1 2 Software installation 18 1 3 Software uninstallation 18 1 4 Software running 18 1 5 Main Menu 19 Chapter 2 Data viewing and exporting to reports 20 2 1 Data Logger monitoring 20 2 2 Data viewing and importing old report 21 2 3 Export result to the report 22 2 4 Exit the software 23 ...

Страница 19: ... in the following figure Click Done B PC Software installation Find the BTLStudioV1 3 4 on the U disk double click to run as shown in the following figure Click Next as shown below Select the corresponding installation path it is best not to install on the C disk the system disk does not have permission to export the report and then click Next Click Next as shown below Click Close and the installe...

Страница 20: ...DFT 6101 Battery Resistance Tester Instruction Manual 19 1 5 Main Menu ...

Страница 21: ...g and exporting to reports 2 1 Data Logger monitoring For the monitoring of the battery Data Logger the Site must be added before monitoring and the establishment process is shown in the following figure After adding site select the adding String as shown in the following figure ...

Страница 22: ... shown 2 2 Data viewing and importing old report Import Data Click the Import Data icon button pop up the interface select a file you can choose a file to import the import success will show success failure will prompt an error as shown in the following figure Select the corresponding imported data double click or right click to view and a new interface will pop up as shown in the following figure...

Страница 23: ...Click the Save Report button in the lower right corner as shown below You can see the data report in excel or RTF format After the report export is completed the report will pop up in Sheet1 you can see the table header test units related parameters result statistics you can also see the histogram of each monomer sheet2 is the detailed data of all Tests as shown in the following figure ...

Страница 24: ...01 Battery Resistance Tester Instruction Manual 23 2 4 Exit the software Click Close Report to exit the data report Click Close Recording to close the Data Logging page Click Exit System to close the software ...