![THOMSON 42WM03ST Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/thomson/42wm03st/42wm03st_service-manual_1109607021.webp)
First issue 10 / 04
21
and BIAS Gamma values are correct, and then press the ”ok” key in remote control. For each color temperature setting,
please repeat the procedure (1)-(3). Only x and y value will change in different color temperature mode (in 8680K, x=288,
y=301; in 10180K, x=270, y=292) and Y values are all the same in each color temperature mode (dark level Y=1.0, bright
level Y=40).
4 .1 Color Temperature setting in YPBPR Mode
1. Turn on Color Analyzer CA-100 and reset CA-100.
2. Switch PDP input signal source to YPBPR mode.
3. Set up Video Pattern Generator (Astro, Model= VG-828H).
Timing set = 640 x 480 @ 60Hz;
Video = Analog (the YPBPR output mode)
Connect PDP YPBPR input connector with Astro to receive YPBPR signal.
4. Dark level and bright level center block definition:
A. Dark level center block definition:
[WINDOW]
Mode %
Format 1
Window
Flicker None
Size H/V
28.5/34.0 (%)
Analog R/G/B
25/25/25 (10 IRE white output pattern)
B. Bright level center block definition:
[WINDOW]
Mode %
Format 1
Window
Flicker None
Size H/V
28.5/34.0 (%)
Analog R/G/B
153/153/153 (60 IRE white output pattern)
5. There are 4 different modes (DVI / RGB / AV / YPBPR) need color temperature setting; there are 3 different color
temperatures (7180K, 8680K and 10180K) in each mode. Each color temperature needs to adjust dark level, bright level,
and R, G, B. The OSD menu for color temperature factory setting can be viewed by following the ”Factory Setting Procedure”.
Factory Setting Procedure:
A. Press (Zoom -) key for over 5 seconds and release.
B. Press (Zoom+) key for over 5 seconds and release.
C. Press ”ok” key.
D. Factory setting OSD menu shows up.
The values showed up on the OSD menu are the factory default setting values. The factory default setting values differ from
each PDP panel module.
6. Put the color analyzer CA-100 in the center of the screen.
4.2 Adjusting procedure:
1. Receive Astro VG-828H YPBPR dark level center block signal (14 IRE), follow the ”Factory Setting Procedure” to go into
factory setting mode and you will see the 7180K color temperature setting OSD menu.
2. 7180K dark level center block adjustment procedure:
A. Press (Zoom -) or (Zoom+) key in remote control to select G-BIAS, and adjust Y=1.1 FL±0.1FL
B. Press (Zoom -) or (Zoom+) key in remote control to select R-BIAS, and adjust x=308±15FL
C. Press (Zoom -) or (Zoom+) key in remote control to select B-BIAS, and adjust y=298±15FL
D. Adjust R/G/B-BIAS, make sure the final value x=308±15FL, y=298±15FL, Y=1.1 FL±0.1FL