TECHNICAL INFORMATION N°2004 - 13
_______________________________________________________________________________________
Chassis : ITC222 - PTV
After Modification
Symptom / Problem Observed :
Cable Clip
Burning of tracks on the PCB of CRT due to a arcing problem.
Solution :
I) Electric :
I-a) Check the presence and add if necessary the following
elements (absent on some versions of PCB) :
- Capacitor 220pF 10% 1KV in position CB185
(red CRT) and CB 385 (blue CRT)
PART N° 25460410.
- Jumper in position JB323 (blue CRT).
I-b) Delete the capacitor CB186 (red CRT) and CB386 (blue CRT).
I-c) If there is a coil in position LB200 (green CRT), replace
by a jumper.
II) Mechanical :
Cut the cable clip and move away the EHT cables of wire
connector BB104, then attach cables EHT with a new cable clip
(see photo).
Caution : The modifications described above can create ringing
effect, visible on blue screen :
On the install menu. If you observe a effect ringing on the left side screen, replace
capacitors CB169, CB269 and CB369 by a jumper and change the coil LP112 (on the power board)
by the new model
PART N° 10857310.
1
1
X
6
5
6
2
4
0
0
1
1
0
B
C
8
1
5
R
C
T
Y
A
5
6
2
4
4
0
0
1
1
0
B
C
8
3
5
R
C
T
Y
A
IRIS Code :
The code mentioned below must be used to report the failure on the warrantee claims form;
we have included it to make fault report easier and the data more reliable.
R.Code
D.Code
Section
Position
Qty
Part code number
Symptom
4
2004/03