background image

Notes

 

 

SF-80

29

Содержание Starville SF-80

Страница 1: ...SF 80 fog machine user manual...

Страница 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 22 10 2013...

Страница 3: ...2 Safety instructions 8 3 Features 14 4 Installation 15 5 Connections and operating elements 16 6 Operating 21 7 Technical specifications 23 8 Troubleshooting 24 9 Cleaning 25 10 Protecting the envir...

Страница 4: ...ctions Save this manual for future reference Make sure that it is available to all persons using this device If you sell the device to other users be sure that they also receive this manual Our produc...

Страница 5: ...on of symbol and signal word indicates a possible dangerous situation that can result in death or serious injury if it is not avoided CAUTION This combination of symbol and signal word indicates a pos...

Страница 6: ...Warning signs Type of danger Warning high voltage Warning flammable substances Warning hot surface Warning suspended load Warning harmful or irritating substances General notes fog machine 6...

Страница 7: ...Warning signs Type of danger Warning danger zone General notes SF 80 7...

Страница 8: ...ent physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is respo...

Страница 9: ...be present Never remove any covers There are no user serviceable parts inside DANGER Electric shock caused by short circuit Do not modify the mains cable or the plug Failure to do so could result in...

Страница 10: ...RNING Risk of burns The generated fog at the fog nozzle is hot and can cause burns Occasionally hot fluid drops may escape from the nozzle The distance of persons and objects to the fog nozzle must be...

Страница 11: ...the floors without a slipping hazard and if necessary remove the condensation WARNING Health hazard caused by fog fluid handling Fog fluid does contain glycols complying with the regulations for food...

Страница 12: ...n approved fluids shall be excluded Do not create fog in closed or poorly ventilated areas Do not expose persons with health problems such as allergic respiratory condi tions asthma to artificial fog...

Страница 13: ...onnecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could r...

Страница 14: ...his fog machine is suitable for use in clubs bars discotheques and on stages Special features of the device n Remote control included n Suitable for mobile use n Large fog fluid container Features fog...

Страница 15: ...sport or storage respectively WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device...

Страница 16: ...5 Connections and operating elements Front panel Connections and operating elements fog machine 16...

Страница 17: ...1 Fog nozzle 2 Fluid container with screw cap 3 Carrying handle and bracket for hanging 4 Tommy screws to adjust the bracket Connections and operating elements SF 80 17...

Страница 18: ...Rear panel Connections and operating elements fog machine 18...

Страница 19: ...crew cap 3 Carrying handle and bracket for hanging 4 Tommy screws to adjust the bracket 5 Remote control cable 6 Fuse holder 7 Mains cable for power supply 8 Liquid level indicator Connections and ope...

Страница 20: ...atus LED indicates that the unit has reached the required operating tempera ture for fog generation 10 Press this button to trigger fog bursts Remote control Connections and operating elements fog mac...

Страница 21: ...on www thomann de and follow their instructions for use First make sure the unit is disconnected from the power supply Open the screw cap of the container and fill in the fog fluid Make sure that no f...

Страница 22: ...s now operational Press the green remote control button to trigger fog bursts When operating always ensure that there is sufficient fluid in the fog liquid container to avoid no load running Disconnec...

Страница 23: ...r power 700 W Fog output approx 70 m3 min Fluid container capacity 1 0 l Warm up time approx 5 min Operating supply voltage AC 230 V 50 Hz Fuse 4 A Dimensions W D H 160 mm 330 mm 130 mm Weight 4 kg Te...

Страница 24: ...dy The unit does not work Check the mains connection and the main fuse The unit does not eject any fog 1 Check the fluid level in the fog container 2 Check the connection to the remote control If the...

Страница 25: ...ery 30 operating hours or if it was not in use for a longer period of time 1 Make sure that the device is disconnected from the mains and completely cooled down 2 Place the unit in a well ventilated p...

Страница 26: ...re is still cleaning fluid present in the container pour it back into the cleaning fluid bottle before refilling fog fluid 9 Connect the device to the mains 10 Wait until the required operating temper...

Страница 27: ...d for recycling Please follow the notes and markings on the packaging This device is subject to the European directive 2012 19 EU Do not dispose of the device with your normal household waste Dispose...

Страница 28: ...Notes fog machine 28...

Страница 29: ...Notes SF 80 29...

Страница 30: ...Notes fog machine 30...

Страница 31: ......

Страница 32: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...

Отзывы: