Symptom
Remedy
The unit does not work
Check the mains power supply and the main switch.
DMX devices don't respond to the DMX con‐
troller
1. Check the DMX ports and cables for proper connection. Many DMX devices
indicate whether they receive a DMX signal or not.
2. Make sure, that the device is not in ‘Standby’ mode.
3. Make sure, that the connected devices are properly configured. Are they set
to DMX mode and are their start addresses in a range of 1…16? Check that by
simply using the
[Full On]
button.
4. Check to see if the DMX cables run near or alongside to high voltage cables
that may cause damage or interference to DMX interface circuits.
If the procedures recommended above do not succeed, please contact our Service Center. You
can find the contact information at
www.thomann.de
.
Troubleshooting