background image

The preheat can be adjusted in a range from 0…50, where a value of 50 corresponds to

approx. 20 %.
In Switch mode (

‘Off’

 to DMX 64, 

‘On’

 from DMX 64), this function is not available.

Proceed as follows to adjust the preheat:
1.

Open the menu 

‘Unit Setup’

‘Preheat Ch1 = 0’

 (see menu overview).

2.

Confirm with the 

[Menu]

 button.

ð

The channel number display flashes.

3.

Select the desired channel with the navigation buttons   or  .

4.

Use the navigation button   to change to the preheat value.

ð

The displayed value flashes.

5.

Adjust the value using the navigation buttons   or  .

6.

Press the 

[Menu]

 button.

ð

The display shows the confirmation prompt 

‘Save Changes?’

.

7.

Confirm the prompt with 

[Menu]

 to save the new settings. To discard the changes, press

the navigation button   to return to the previous menu level.

Setting the preheat

Operating

 

 

dimmerpack

24

Содержание STAIRVILLE D1210H

Страница 1: ...D1210H dimmerpack user manual...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 10 01 2017 ID 153386 V3...

Страница 3: ...ions 6 1 3 Symbols and signal words 6 2 Safety instructions 8 3 Features 13 4 Installation and starting up 14 5 Connections and operating elements 16 6 Operating 20 7 Technical specifications 30 8 Plu...

Страница 4: ...ons and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this...

Страница 5: ...word search Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms...

Страница 6: ...kets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF 1 3 Symbols and signal words In this section y...

Страница 7: ...l result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damag...

Страница 8: ...idered to be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient...

Страница 9: ...e like from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas...

Страница 10: ...nt at cable ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified elec...

Страница 11: ...direct heat source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid or moist...

Страница 12: ...nd that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms o...

Страница 13: ...X 512 n Preheat dimmer curve and maximum voltage can be adjusted individually n Indicators for temperature and operation n Test function n Intelligent cooling control large cooling ribs n Single chann...

Страница 14: ...the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards The device is designed for mounting in 19 racks it oc...

Страница 15: ...r DMX device Connect the output of the first DMX device to the input of the second and so on to form a series connection Make sure that the output of the last DMX device in the chain is ter minated by...

Страница 16: ...5 Connections and operating elements Front panel Connections and operating elements dimmerpack 16...

Страница 17: ...deactivated O OFF 2 L1 L3 Voltage indicators of blocks L1 L3 The LEDs of the connected blocks light red as soon as mains power is applied to the device 3 1 12 Voltage indicators of channels 1 12 The...

Страница 18: ...6 Menu Button to open the main menu and confirm display values 7 Navigation buttons Buttons to navigate the device menu Connections and operating elements dimmerpack 18...

Страница 19: ...r outputs 2 16 pin Harting industrial connectors note the device label when connecting the cables 9 Fan 10 Power cord with 5 pin CEE plug 32 A 3 230 V Rear panel Connections and operating elements D12...

Страница 20: ...Hazardous voltage may be present at cable ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only b...

Страница 21: ...Menu overview Operating D1210H 21...

Страница 22: ...3 Select the desired channel with the navigation buttons or 4 Use the navigation button to change to the curve value The displayed value flashes 5 Select the desired setting with the navigation button...

Страница 23: ...mber display flashes 3 Select the desired channel with the navigation buttons or 4 Use the navigation button to change to the voltage value The displayed value flashes 5 Adjust the value using the nav...

Страница 24: ...The channel number display flashes 3 Select the desired channel with the navigation buttons or 4 Use the navigation button to change to the preheat value The displayed value flashes 5 Adjust the value...

Страница 25: ...buttons or 4 Use the navigation button to change to the set DMX address The displayed value flashes 5 Adjust the value using the navigation buttons or 6 Press the Menu button The display shows the co...

Страница 26: ...ch on mode 1 Open the menu Unit Setup PowerOn see menu overview 2 Confirm with the Menu button The current setting appears on the display 3 Select the desired Switch on mode with the navigation button...

Страница 27: ...display flashes 3 Select the desired channel with the navigation buttons or 4 Change with the navigation buttons and between channel number and channel value 5 Press the Menu button to exit Test mode...

Страница 28: ...ividual blocks see menu overview Select the desired block with the navigation buttons or Above a temperature of 45 C the internal fans will be switched on The fan power will be increased continuously...

Страница 29: ...MX Signal see menu overview When the signal is received correctly the display will show DMX Signal OK On a faulty signal No DMX Signal appears In this case check the connecting cables and DMX settings...

Страница 30: ...Three phase connection max 32 A per phase Channel fuse 1 circuit breaker per channel 10 A C characteristic Signal input DMX 512 via 3 pin XLR socket Outputs 2 Harting industrial connectors 16 pin Dime...

Страница 31: ...into a socket the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR...

Страница 32: ...Please follow the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste...

Страница 33: ...Notes D1210H 33...

Страница 34: ...Notes dimmerpack 34...

Страница 35: ......

Страница 36: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: