TI120 Series Variable Frequency Drive
Operation Keyboard and Trial Operation
- 23 -
Function code
Setting range
Application description
P01.05:
start
mode selection
0: start frequency starting
Starting from the setting frequency of P01.06,
and after the holding time of P01.07, start to
accelerate to the setting frequency for constant
speed operation through acceleration time.
However, when P01.09 is set to non-0, start DC
brake firstly, and then start from P01.06
frequency.
1: speed search starting
After receiving the start command, the variable
frequency drive starts to search for the actual
speed of the motor, then starts to run from the
searched speed, and judges whether the
searched speed is greater than or less than the
set frequency so as to speed down or
accelerate the operation.
P01.10:
stop
mode selection
0: slow down and stop
The variable frequency drive receives the stop
command and starts to slow down; when the
speed is reduced to the stop DC brake starting
frequency of P01.11 and when P01.13 is set to
non-0, it starts to stop DC brake; otherwise, it
continues to slow down until the output
frequency of the variable frequency drive is 0,
and the stop is completed.
1: free stop
When the variable frequency drive receives the
stop command, it immediately blocks the output
of the variable frequency drive, and the motor
stops in a free stop mode.
3.2.4 Frequency source selection
1)
Main given setting mode of frequency
Function
code
Main given mode of
frequency
Factory value
0
P00.01
Setting
range
0
Number setting (P00.00)+ terminal Up/Down or keyboard
▲/▼ adjustment
1
Analog input AI1