Setting Up the P120
6.
If the
loose leads stranded Power Input cable
is used,
first
connect the
black
lead of the cable to the ground terminal of the power source. Then, connect the
red
lead of the cable to the positive terminal of the power source.
Caution:
This connection order is important to prevent accidental damage to
equipments and injury when touching of the two leads together to the positive power
source.
7.
Now the power source and then the equipment could be turned on.
To disconnect, first power off the equipment and then the power source (if possible).
Caution:
If the Power Input cable with
loose leads
is used,
first
remove the
red
lead,
follow by the
black
lead
. Again, this disconnection order is important.
The next figure is an example setup of the P120 with loose lead stranded at the input end
and LEMO connector at the output.
Operation Consideration and Maintenance
The P120 should be operated only within its specified operating temperature range of 14
to 131°F (-10 to 55°C). The unit should be store within its specified non-operating
temperature range of -40 to 160°F (-40 to 71°C).
Caution:
Do not expose the device to water in any condition or operate in prolong high
humidity environment, as doing so might result in personal injury due to electrical shock
as well as damage to the device.
13
ThinkRF P120 Vehicular Power Conditioner - User's Guide v1.1