Thinklogical VX640 Скачать руководство пользователя страница 25

 

VX640 Router Manual, Rev. D 

20 

August, 2013 

 

 

Step 3 
Once the module is completely seated, hand-tighten the thumbscrews.  

Warning!

  Do not tighten the thumbscrews with a screwdriver.

  

How to Install or Replace an Interconnect Module 

Note: Replacing the Interconnect Module will interrupt service. 

To  replace  the  Interconnect  Module,  the  front  door  and  front  panel  must  first  be  removed.    (See 
Appendix C, page 31.) 

 

Step 1  
Turn both front door latches one quarter turn clockwise (arrow on knob pointing up) to release the door. 

 

Step 2  
While holding the door steady with one hand, pull down the upper spring-loaded hinge release and pull 
the  upper  portion  of  the  door  outward  until  the  latch  clears  the  mounting  hole.  The  door  can  now  be 
removed and set aside. 

Warning!   

KEEP  THE  DOOR  CLOSED  WHEN  IN  USE!    The  VX640  Front  Door  contains  air-

flow baffles that are integral to the router’s cooling system.  Do not leave the front door off 
the  chassis  for  an  extended  length  of  time  if  the  unit  is  running.    Keeping  the  front  door 
open for an extended period of time will lead to a malfunction of the VX640. 

 

Step 3  
There are two thumb screws holding the front panel to the chassis.  Loosen the thumb screws, remove 
the front panel and set it aside.   

 

Step 4  
There  are  two  thumbscrews  on  the  Interconnect  Module;  turn  the  thumbscrews  counterclockwise  until 
they disengage from the chassis.  Pull the Interconnect Module out using both black ejector handles. 

 

Step 5 
Place the new module upright so that the four Status LEDs are at the bottom. Grasp the module 
by  the  handles.  The  card  should  slide  in  freely  until  it  reaches  the  backplane  connector.    At this 
point, use just enough force to firmly engage the card with the mating connector. 

Warning!

  If the module does not slide easily into the connector, do not force it!  Damage 

may occur.  Remove the card and start over.  

Step 6 
Once the module is completely seated, hand-tighten the thumbscrews.  

Warning!

  Do not tighten the thumbscrews with a screwdriver.

  

Step 7 
Replace the front panel that was removed in Step 3

 

Step 8 
Replace the front door that was removed in Steps 1 and 2

Содержание VX640

Страница 1: ...KVM Matrix Switch Thinklogical LLC 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 Fax 1 203 783 9949 www thinklogical com router...

Страница 2: ...rights reserved Printed in the U S A Thinklogical LLC 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 All trademarks and service marks are property of their respective o...

Страница 3: ...uirements 12 Pluggable SFP 12 Input Output Cards 13 PART 2 SET UP AND INSTALLATION 15 Set Up 15 Connecting to the VX640 16 Fiber Optic Cable 16 Requirements 16 Handling Fiber Optic Cable 16 Connecting...

Страница 4: ...y 24 Standards with Which Our Products Comply 24 Supplementary Information 24 Product Serial Number 25 Connection to the Product 25 PART 4 THINKLOGICAL SUPPORT 25 Customer Support 25 Website 26 FTP Si...

Страница 5: ...r to starting the hardware assembly Part 4 Thinklogical Support Thinklogical provides the best customer support available If you have any questions or need to contact the company please refer to this...

Страница 6: ...nk SDI USB 1 1 USB 2 0 and audio Thinklogical s VX640 Router includes 2 Redundant Current Sharing Power Supply Modules for the Upper Cage 2 Redundant Current Sharing Power Supply Modules for the Lower...

Страница 7: ...ology has the ability to transport every frame of a 1920 x 1200 60Hz or higher video stream with no compression along with all desktop peripherals keyboard mouse etc including 480Mbps USB 2 0 with no...

Страница 8: ...G Video Redundant Hot Swappable and Current Sharing Power Supply Modules Hot Swappable 20 Port Scalability for In and Out Cards Hot Swappable SFP Optical Port Connections Hot Swappable Fan Tray with A...

Страница 9: ...e Fan Tray VXM 000027 Spare Power Module VXM 000028 Data Input Output Card 20 Ports VXM DI0R20 Chassis Dimensions Rack Size Width EIA 19 482 6 mm Height 28 RU 49 1244 6 mm Depth 16 07 408 2 Depth with...

Страница 10: ...Description VX640 Chassis VXR 000640 Velocity Matrix Router 640 Chassis includes Upper and Lower Cage Backplanes Upper and Lower Interconnect Boards 8 Switch Cards 1 Fan Tray 1 Controller Card and 4...

Страница 11: ...onnect Card is modular but not hot swappable It can be easily replaced in the field but the VX640 will need to be shut down Detailed Front View of VX640 Warning KEEP THE DOOR CLOSED WHEN IN USE The VX...

Страница 12: ...le can be accessed through the front of the router See the DIP Switch Instructional Guide in Appendix C Setting the DIP Switch Instruction Guide page 31 for detailed instructions on how to access the...

Страница 13: ...from right Card 1 to left Card 8 These cards contain the cross point fabric of the router allowing for 8 possible paths to make connections In the event that a Switch Card fails some con nections may...

Страница 14: ...VX640 Router Manual Rev D 9 August 2013 Detailed Rear Panel View of VX640...

Страница 15: ...signed for easy replacement without interrupting system functionality The Fan Tray forces air into the chassis through air baffles in the front door This cools the vertically mounted I O cards the int...

Страница 16: ...rator Software can be used to control the VX Router via the LAN port Ethernet Control If the VX640 KVM Matrix Switch is to be controlled via Ethernet it will require a static IP address This value can...

Страница 17: ...on AMX serial access A Back Up Controller Card is optional to ensure uninterrupted functionality if the Primary Controller Card fails or needs to be replaced The Primary Controller Card should always...

Страница 18: ...PUT Input Output Cards The hot swappable Input Output I O cards provide excellent in service expansion capabilities in convenient sets of 20 ports per card allowing re configuration without interrupti...

Страница 19: ...m of one I O Card 20 x 20 and a maximum of 32 I O Cards Each VX640 I O card contains 20 ports When fully configured the VX640 will contain 16 I O cards in the Upper Card Cage and 16 I O cards in the L...

Страница 20: ...umb screws are finger tight so that all the modules are properly held in the chassis Step 1 Carefully remove the VX640 KVM Matrix Switch from its shipping container Inspect the router to make certain...

Страница 21: ...condition Warning Do not open or remove the front door for more than a few minutes when the unit is powered The door includes air flow baffles that are part of the cooling system The Switch Card inte...

Страница 22: ...ting switching and extension of video and high speed data peripherals to remote destinations with ease Connecting to the Receiver The Velocity Receiver serves as the Destination desktops theaters conf...

Страница 23: ...and must end with a carriage return CR and line feed LF or just a line feed LF The characters are not echoed The serial port is configured for 9600 baud 1 stop bit no parity and no flow control The ne...

Страница 24: ...ded period of time The timeouts can be set in increments of one second Typical timeouts are in the order of 10 seconds Upgrades Firmware upgrades are available through Thinklogical For technical assis...

Страница 25: ...ength of time if the unit is running Keeping the front door open for an extended period of time will lead to a malfunction of the VX640 Step 3 There are two thumb screws holding the front panel to the...

Страница 26: ...seated hand tighten the thumbscrews Warning Do not tighten the thumbscrews with a screwdriver How to Install or Replace a Controller Card Note When using a single Controller the top Controller slot is...

Страница 27: ...h black handles Step 3 Place the new module so that the aluminum housing is on the bottom Hold the new Fan Tray by the black handles and slide the aluminum housing into the black card guides Warning D...

Страница 28: ...over PART 3 REGULATORY SAFETY REQUIREMENTS Symbols Found on Our Products Markings and labels on our products follow industry standard conventions Regulatory markings found on our products comply with...

Страница 29: ...cs EN61000 4 2 1995 Electro Static Discharge Test EN61000 4 3 1996 Radiated Immunity Field Test EN61000 4 4 1995 Electrical Fast Transient Test EN61000 4 5 1995 Power Supply Surge Test EN61000 4 6 199...

Страница 30: ...using a keyboard that is noise susceptible a ferrite ring on the keyboard cable may be needed to comply with Immunity Requirements Product Serial Number Thinklogical products have a unique serial num...

Страница 31: ...ts and files In addition to technical documents it contains ISO files that may be used to burn copies of the CDs we include with our routers the X4 Configurator manual and an installable version of X4...

Страница 32: ...ovide return contact information Product Support Thinklogical s support personnel are available Monday through Friday from 8 30am to 5 00pm Eastern Time Zone If your application requires assistance at...

Страница 33: ...d CT 06460 USA PH 1 800 291 3211 USA only Our Address If you have any issue with a product have product questions or need technical assistance with your Thinklogical system please call us at 1 800 291...

Страница 34: ...VX640 Router Manual Rev D 29 August 2013 APPENDIX A VX640 QUICK START GUIDE...

Страница 35: ...VX640 Router Manual Rev D 30 August 2013 Appendix B Setting the DIP Switch Instruction...

Страница 36: ...mechanisms to ensure that only trusted administrators have access Thinklogical s VX Routers use two methods for secure routing One is known as Restricted Switching and the other is known as Partitioni...

Страница 37: ...riage Return character code 13 CR Line Feed character code 10 LF The VX Router will interpret the Restricted Switching Table csv file during the boot up Any errors that occur during the Restricted Swi...

Страница 38: ...following command s on the Primary Controller F var local router restrict upstream csv ssh secondary cat F diff bq F echo Files Match F var local router restrict downstream csv ssh secondary cat F di...

Страница 39: ...in the BLACK GREEN networks Destination workstations in the BLACK network can control source computers in the BLACK network only Restricted switching is configured via firmware loaded into the VX Rou...

Страница 40: ...rtition and not across partitions The maximum number of partitions is the number of ports that make up the VX Router 80 160 320 640 A VX40 or VX80 Router can be configured with up to 80 partitions a V...

Страница 41: ...ing Tables files for the Router are stored on the Controller Card at the following location var local router partition upstream csv var local router partition downstream csv Note that the downstream c...

Страница 42: ...are using an MD5 password it should be approximately 15 characters long With DES passwords use the maximum eight character length MIX UPPER AND LOWER CASE LETTERS Passwords are case sensitive so mixin...

Страница 43: ...the Restricted Switching feature For example the VX640 Matrix Router Network Diagram should be configured with the following csv file I 1 2 I 2 2 O 2 2 I 42 2 O 41 2 O 42 2 I 5 1 O 5 1 I 45 1 O 45 1 T...

Страница 44: ...0 Router Manual Rev D 39 August 2013 DVI from CPU DVI to Local Display DVI to Display DVI to Display DDC DVI to Display DVI to Display DDC DVI from CPU DVI to Local Display VX640 Video Secure Applicat...

Отзывы: