24
Â
Ensure that you have fitted the
union (‘N’) to the upper part of the
hood using the packaged two
screws supplied inside the packing
(Fig. 1 – on right). Using a 125 mm
diameter pipe, connect the union
(N) on the upper part of the hood
(see Fig. 1) to the discharge outlet
for cooking vapours with a cross-
section of at least 150 cm
²
.
Â
PLEASE NOTE: If there is no
discharge outlet and the hood is to
be fitted to an outside wall of the
building, make a hole in the wall
that is large enough to fit a wind
and rain-proof shutter with a cross
section of at least 150 cm
²
and
connect this to the outlet union of
the unit by means of a pipe.
__________________________________________________________________________________________________________________________________________________________________________________________________________________________
.
AIR PURIFIER (RECIRCULATION) OPERATION - Installation
Instructions
The cooker hood can be converted to work as an air purifier in the
event that there is no provision for an external air discharge duct.
In this case, air is recycled through the vent ‘R’ (Fig. 1 – above).
When using the unit as an air purifier, you need to install two active
carbon filters to absorb cooking vapours (please see page 11).
* Note on what to do if your Cooker Hood is the version that
comes with a BRACKET.
Please note: For the extraction function, you will
need to connect a 125 mm diameter outlet chimney to
the spigot ‘N’ in fig. 1 above. This pipe is not provided
with your cooker hood. See figure on left.