ThingsLog LPMDL-1102 Скачать руководство пользователя страница 15

 

 

 

 

Figure 11 Flow consumption graph 

8.4.3

Cumulative graph 

 

Figure 12 Cumulative consumption graph 

8.4.4

Data export  

The system supports readings data export from a certain time range in CSV file format.  

Visit us at 

www.thingslog.com

; (+359) 875 32 80 70; 

[email protected]

 

 

Содержание LPMDL-1102

Страница 1: ...1102 NB IoT Data logger iTransformers Labs Ltd 11 Magnaurska shkola str fl 3 office 315 Hightech Business Park BIC IZOT 1784 Sofia Bulgaria Phone 359 875 32 80 70 Email info thingslog com Visit us at...

Страница 2: ...g the batteries 10 User guide 10 Associating logger to a profile 10 Network coverage and service 11 Initial configuration ThingsLog LPMDL 1102 11 Normal operation mode short functional description 14...

Страница 3: ...or connecting analog sensors with 4 20 mA output An example could be connecting two pressure sensors or one pressure and one temperature sensor Combined monitoring LPMDL 1102 can fulfill use cases whe...

Страница 4: ...ation Pulse metering the logger supports pulses generated by reed contacts hol sensors or S0 pulse outputs of water gas and electricity meters Analog sensor metering The logger supports analog sensors...

Страница 5: ...conditions for use indoors or outdoors without prolonged exposure to direct UV radiation for altitudes up to 2000 m for ambient temperatures from 40 C to 60 C with continuous exposure to temperatures...

Страница 6: ...al package Transportation is allowed to happen accidentally at temperatures below 20 C but not more than 8 hours Protect against shocks and avoid extreme conditions Subsequent maintenance Once install...

Страница 7: ...5 Physical installation Figure 1 Logger outlook and dimensions Visit us at www thingslog com 359 875 32 80 70 sales thingslog com...

Страница 8: ...logger you will need a wall with stiff flat surface close to the meter or the sensor which you would like to measure Mark and drill holes with size 4x25 mm for attaching the logger to the wall Attach...

Страница 9: ...Figure 3 Logger input output ports Figure 4 LPMDL 1102 wiring scheme Visit us at www thingslog com 359 875 32 80 70 sales thingslog com...

Страница 10: ...to us for battery replacement 8 User guide 8 1 Associating logger to a profile 1 In order to perform the initial configuration you should have an account for ThingsLog IoT platform If you don t have a...

Страница 11: ...nd service In order to work ThingsLog data loggers need network connection Prior performing the initial configuration ensure that there is NB IoT network coverage in your area If you are not sure whic...

Страница 12: ...Figure 7 Menu Devices 3 From the menu choose Config then a similar configuration dialog will appear Figure 8 Configuration dialog Visit us at www thingslog com 359 875 32 80 70 sales thingslog com...

Страница 13: ...ber of digits equals to the number of digits on the display of the meter Fraction Number of digits after the decimal pointer on the display of the meter Initial counter Initial value of the counter of...

Страница 14: ...on mode short functional description Once configured the logger will start to collect and transmit readings from the attached sensors The logger supports the following main functionalities 8 4 1 Readi...

Страница 15: ...8 4 3 Cumulative graph Figure 12 Cumulative consumption graph 8 4 4 Data export The system supports readings data export from a certain time range in CSV file format Visit us at www thingslog com 359...

Страница 16: ...file format 8 5 Normal operation dashboard After login the user will be redirected to a dashboard where the user can verify the operational status of the loggers Visit us at www thingslog com 359 875...

Страница 17: ...certain threshold over certain long period of time For example the logger has detected a NON zero consumption over 6 consecutive hours HIGH_CONSUMPTION alarm indicating consumption higher than a cert...

Страница 18: ...ero consumption through certain time period For there is no consumption for 24 hours Could potentially indicate a fault meter DEVICE_REMOVED alarm indicating that the meter has been disconnected from...

Отзывы: