THIESEN ERB2-H Скачать руководство пользователя страница 2

Electric power supply / cable connection to the aircraft system (12 Volts DC)

The best connection is solder with additional shrinking of the soldering joint with a shrink hose (enclosed). Only use electronic solder. Never use 
cored solder. It contains acids which cause corrosion!

Synchronization

The ERB2-H has an additional yellow synchronisation cable to synchronize with EPL2 or EPTA. Therefore connect the yellow cable of the 
EPTA (or EPL2) with the yellow cable of the ERB2-H (additionally with ELL50 if required). The intelligent synchronisation scales the light pulse 
(and thereby the current pulse). This will prevent the battery respectively the generator by constant current consumption. 

If you do not use the 

synchronisation, connect the yellow cable with +12V (red cable).

Important notes:

Carefully install the cables inside the rudder and / or the fuselage. Connect the cables professionally to the aircraft system (RED = 
positive, 

 

 

). Important: connect the braiding screen of the 

BLACK = negative,

yellow = synchronisation,

green = FLARM interface

FLARM-cable only at the ground of the Power-FLARM to avoid ground loops and therefore interferences.

The twisted wires should be fixed. Protect the circuit with a 5 Amps fuse. Do not use luster terminals. Suitable connectors are available at pilot‘s 
shops.

Servicing / maintenance

Should the ERB2-H be scratched, use a good polish to refurbish the damages. With slightly deeper scratches use wet sandpaper with very fine 
granulation (800-1000) carefully polish again. Do not use aggressive chemicals like gasoline or solvent.

For day to day cleaning use soap water!

Some insect removers and detergents forces embrittlement of epoxy based plastics and laminates.

Use only aircraft certified products. If the aircraft can not hangarized, please cover the lamps to prevent surface aging!

Im Tiegel 9

36367 Wartenberg 

Deutschland

Tel.: +49 (0) 66 41 - 979 - 0

eMail: [email protected]

www.thiesen-electronics.com

www.flugzeuglichter.de

THIESEN

E L E C
TRONICS
G M B H

5.000 hours or max. 3 years assured 

luminous duration

Subject to changes without notice

Made in Germany

Wiring Diagramm:

+

_

12 Volt Battery

Fuse 5 A

Fuse 5 A

Switch

Switch

ACL4
ERB2

ELL50
ETL50
ELL60
ELL80is

Left 
EPTA-LSA

Right 
EPTA-LSA

gelb / yellow

Positionslicht / Positon Light

Landescheinwerfer / Landinglight

Antikollisionslicht / Anticollision Light

ACL-Funktion / ACL-Function

5

4

3

2

1

9

8

7

6

Power-FLARM-Ausgang / Power-FLARM-Output

Verdrillte Leitungen / twisted cable 

=

rot / red 

= Plus 12 Volt

schwarz / black = Minus 12 Volt
gelb / yellow 

= Synchronization-Cable

blau / blue 

= Plus 12 Volt Landescheinwerfer / Landinglight

grün / green 

= FLARM-Interface

Technical Data

:

Operating voltage

10-17 volts (DC), typically 12.8 - 13.4 volts

 : 

Input

approx. 16 watts

 

Fuse

5 ampere (fusible cut-out or automatic fuse)

 

Dimensions

 

:   47 (63,5)  x 77 mm (D x H)

Weight

approx. 125 grams with connecting cables

 

Warranty

5,000 operating hours or max. 3 years

 

Отзывы: