Electric power supply / cable connection to the aircraft system (12 Volts DC)
The best connection is solder with additional shrinking of the soldering joint with a shrink hose (enclosed). Only use electronic solder. Never use
cored solder. It contains acids which cause corrosion!
Synchronization
The ERB2-H has an additional yellow synchronisation cable to synchronize with EPL2 or EPTA. Therefore connect the yellow cable of the
EPTA (or EPL2) with the yellow cable of the ERB2-H (additionally with ELL50 if required). The intelligent synchronisation scales the light pulse
(and thereby the current pulse). This will prevent the battery respectively the generator by constant current consumption.
If you do not use the
synchronisation, connect the yellow cable with +12V (red cable).
Important notes:
Carefully install the cables inside the rudder and / or the fuselage. Connect the cables professionally to the aircraft system (RED =
positive,
). Important: connect the braiding screen of the
BLACK = negative,
yellow = synchronisation,
green = FLARM interface
FLARM-cable only at the ground of the Power-FLARM to avoid ground loops and therefore interferences.
The twisted wires should be fixed. Protect the circuit with a 5 Amps fuse. Do not use luster terminals. Suitable connectors are available at pilot‘s
shops.
Servicing / maintenance
Should the ERB2-H be scratched, use a good polish to refurbish the damages. With slightly deeper scratches use wet sandpaper with very fine
granulation (800-1000) carefully polish again. Do not use aggressive chemicals like gasoline or solvent.
For day to day cleaning use soap water!
Some insect removers and detergents forces embrittlement of epoxy based plastics and laminates.
Use only aircraft certified products. If the aircraft can not hangarized, please cover the lamps to prevent surface aging!
Im Tiegel 9
36367 Wartenberg
Deutschland
Tel.: +49 (0) 66 41 - 979 - 0
eMail: [email protected]
www.thiesen-electronics.com
www.flugzeuglichter.de
THIESEN
E L E C
TRONICS
G M B H
5.000 hours or max. 3 years assured
luminous duration
Subject to changes without notice
Made in Germany
Wiring Diagramm:
+
_
12 Volt Battery
Fuse 5 A
Fuse 5 A
Switch
Switch
ACL4
ERB2
ELL50
ETL50
ELL60
ELL80is
Left
EPTA-LSA
Right
EPTA-LSA
gelb / yellow
Positionslicht / Positon Light
Landescheinwerfer / Landinglight
Antikollisionslicht / Anticollision Light
ACL-Funktion / ACL-Function
5
4
3
2
1
9
8
7
6
Power-FLARM-Ausgang / Power-FLARM-Output
Verdrillte Leitungen / twisted cable
=
rot / red
= Plus 12 Volt
schwarz / black = Minus 12 Volt
gelb / yellow
= Synchronization-Cable
blau / blue
= Plus 12 Volt Landescheinwerfer / Landinglight
grün / green
= FLARM-Interface
Technical Data
:
Operating voltage
10-17 volts (DC), typically 12.8 - 13.4 volts
:
Input
approx. 16 watts
:
Fuse
5 ampere (fusible cut-out or automatic fuse)
:
Dimensions
: 47 (63,5) x 77 mm (D x H)
Weight
approx. 125 grams with connecting cables
:
Warranty
5,000 operating hours or max. 3 years
: