THIESEN ACL3 Скачать руководство пользователя страница 2

Electric power supply / cable connection to the aircraft system (12 Volts)

The best connection is solder with additional shrinking of the soldering joint with a shrink hose (enclosed). Only use solder for 
electronic soldering  never use cored solder. It contains acids which cause corrosion!

The ACL is provided with overload protection. In case of over voltage the protector switches off the ACL. After reset or voltage 
drop  the ACL  is  again  fully  functional. The  automatic  overload  protector  shall  be  activated  at  a  voltage  above  18  Volts. 
(If the voltage reduces to a value below 18 Volts, the ACL will again be functioning)

Servicing / maintenance

Should the ACL be scratched, use a good polish to refurbish the damages. With slightly deeper scratches use wet sandpaper 
with very fine granulation (800-1000) carefully polish again. Do not use aggressive chemicals like gasoline or solvent.

For day to day cleaning use soap water!

Some insect removers and detergents forces embrittlement of epoxy based plastics and laminates. Use only aircraft certified 
products.

If the aircraft can not hangarized, please cover the lamps to prevent surface aging!

Important notes 

Carefully mount the cables inside the rudder and/or the fuselage. Connect the cables professionally to the aircraft system 

(RED = positive, 

)

 and to a 5 Amps fuse protection. Luster terminals are not suitable to connect cables. 

There is a good selection of suitable crimp connections in various shops.

BLACK = negative

Pasting

Apply only as much silicone as required to paste the ACL plane. (see illustration 2). 
After fixing the EPL to the required position, slightly tighten the screw. With your moistened finger using dish liquid clean off any 
laterally dispensable silicon, a smooth transition can be modeled between the wing and the EPL.

Silicone needs time to cure (vaporization of acetic acid). The best results are achieved at a temperature of 20 deg. Celsius (68 
deg. Fahrenheit). Just follow the handling instructions of the silicone. The final firmness (stability) will be reached after a few 
days.

Technical data

 

Operating voltage: 10-17 volts (DC), typically 12.8 - 13.4 volts 
Input

: approx. 20 watts

Fuse

: 5 ampere (fusible cut-out or automatic fuse)

Dimensions

: 61 x 46 x 52 mms 

Drill hole

: 4.5 mm

Weight

: approx. 110 grams with connecting cables

Warranty

: 5,000 operating hours or max. 3 years

Illustration 2

Subject to changes without notice

apply silicone here

apply silicone here

lateral view

lateral view

mounting at the bottom of the fuselage

mounting on top of the fuselage

5.000 hours or max. 3 years

assured luminous duration

Made in Germany

Im Tiegel 9
36367 Wartenberg 
Deutschland
Tel.: +49 (0) 66 41 - 979 - 0
eMail: [email protected]
www.thiesen-electronics.com
www.flugzeuglichter.de