Command BD
<id>BD<para5>
Setting duplex-mode (full- [“0”] / half-duplex [“1”]).
Description:
Setting for the using of a so-called 4-wire- (full-duplex, common called RS422)
or 2-wire-communication (half-duplex, RS485).
Value range:
0,1
Initial value:
0 (full-duplex)
Note:
•
We recommend concerning the simplicity the use of full-duplex
communication
•
If you change the duplex-mode please bear in mind that mostly a
change of wiring and setting of the interface (-converter) is necessary.
•
The latency period is 20ms. This means that after sending of a
command within 20ms the switching of the direction must happen.
And after receiving a answer from the sensor at the earliest time of
20ms a command can be send.
•
Half-duplex operation: An idle-state of at least 0,2 V is to be caused
by respective resistances of the opposite site (normally available in
the interface converter
Command ID
<id>ID<para5>
Setting of the device address for the communication.
Description:
After setting of the address in the future this new <id> must be used for each
new command.
Value range:
0…99
Initial value:
0
7.2.2 Reset / Version commands
Command RS
<id>RS00001
Reset of the sensor.
Description:
Re-start of the sensor. Note: command mode has to be set to configuration
before (see “KY”, CH.
7.2.1
)
Value range:
1
Initial value:
0
Command SV
<id>SV
Request of the software version.
Description:
Output of the software version (example reply: „!00SV00203“ -> V2.03)
Value range:
-
Initial value:
-