Thies CLIMA 5.4103.20.041 Скачать руководство пользователя страница 8

 

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany    

 

 

021335/05/18  

Phone +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·

www.thiesclima.com

  

 

Page 8 of 12 

8  Technical Data 

Measuring Value 

Precipitation intensity (mm / min) 

Output 

Constant current, depending on measuring value, between  
4.0 mA and 20.0 mA 

Measuring range, Output, 
Transfer function 

Measuring range 

Output 

Function

1)

 

Segment 1  0 ….... 0.01 mm / min  =  4.0 ….. 8.0 mA 

0,0025 *x -0,01 

Segment 2  0.01 …0.1   mm / min  =  8.0 … 12.0 mA 

0,0225 *x -0,17 

Segment 3  0.1 …. 1.0   mm / min  = 12,0 … 16.0 mA 

0,225 *x -2,6 

Segment 4  1.0 ... 10.0  mm / min 

= 16.0 … 20.0 mA 

2,25 *x -35 

max. load 

400 Ohm 

Active sensor surface 

25 cm

2

 

Minimum drop size 

0,2 mm 

Operating voltage 

24 V AC/DC 

±

15 % 

Operating current 
 

approx. 350 mA @ 20°C ambient temperature 
max. approx. 1 A 

Ambient temperature 

-30 ... +60°C 

Protection 

IP 65 acc. to DIN 40050 

Weight 

0.4 kg 

Connection 

See model 

1)

Function for calculation: 

Depending on the segment, where the measured current fits in, the respective function must 
be applied, wherein for “x” the measured value in mA is entered. 

 

 

Содержание 5.4103.20.041

Страница 1: ...Precipition Sensor Instruction for Use with analogue Intensity Output 5 4103 20 041 5 4103 20 641 5 4103 20 741 Dok No 021335 05 18 T H E W O R L D O F W E A T H E R D A T A...

Страница 2: ...e product is designed for a specific application as described in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by...

Страница 3: ...and Mode of Operation 4 4 Recommendation Side Selection Standard Installation 5 5 Installation 6 5 1 Mechanical Mounting 6 5 2 Electrical Mounting for Precipitation Sensor with Cable Gland 6 5 3 Elect...

Страница 4: ...vided into 4 linear characteristic segments which show a tenth of the slope of the more sensitive segment Thus it is possible to represent an intensity range from approx 0 001mm min light drizzle up t...

Страница 5: ...79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 5 of 12 4 Recommendation Side Selection Standard Installation Order No 5 4103 20 041 5 4103 20 641 Clamp connection Order No 5...

Страница 6: ...he precipitation can easily reach the sensor field and that the instrument while operating is not exposed to strong vibrations or shocks The pictured tube is not included in delivery 5 2 Electrical Mo...

Страница 7: ...g wire 5mm 5 Soldering wire to the insert 6 Positioning shield in cable clamp 7 Screwing on cable clamp 8 Assembling remaining parts acc to upper plan 9 Tightening pull relief of cable by screw wrench...

Страница 8: ...mA 0 0025 x 0 01 Segment 2 0 01 0 1 mm min 8 0 12 0 mA 0 0225 x 0 17 Segment 3 0 1 1 0 mm min 12 0 16 0 mA 0 225 x 2 6 Segment 4 1 0 10 0 mm min 16 0 20 0 mA 2 25 x 35 max load 400 Ohm Active sensor...

Страница 9: ...bH Co KG Hauptstra e 76 37083 G ttingen Germany 021335 05 18 Phone 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 9 of 12 9 Dimension diagram 5 4103 20 041 5 4103 20 64...

Страница 10: ...of 12 10 Accessories Optional Power Supply Unit 9 3388 00 002 The power supply unit provides for the current supply of the Precipitation Sensor It supplies the necessary operation voltage for the ele...

Страница 11: ...to the making available on the market of electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 Mar...

Страница 12: ...001 65 info thiesclima com www thiesclima com Page 12 of 12 Please contact us for your system requirements We advise you gladly ADOLF THIES GMBH CO KG Meteorology and environmental metrology Hauptstra...

Отзывы: