![Thies CLIMA 4.3519 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/thies-clima/4-3519-series/4-3519-series_instructions-for-use-manual_1106926009.webp)
9 - 14
021075/08/11
8 Technical
Data
Measuring range
See model
Resolution 0,1
m/s
Starting velocity
0,5 m/s
Accuracy
±
0,5 m/s or
±
3% of measuring value
Measuring principle
Opto-electronic (slotted disc)
Electrical output
See model
Load
for current output (mA)
for current output (V)
max. 500 Ohm (for operating voltage
>
15 V DC)
min. 1 K
Ω
Electrical
supply for electronics
U: 9…30 V DC oder 24 V AC/DC
I: 0,05A
P: 1,5 W
*für 0 -10 V output
U: 13…30 V DC oder 24 V AC/DC
I: 0,05A
P: 1,5 W
Electrical
supply for heating
4.3519.00/01/02/04/05/20/39.xxx U: 24V AC/DC, 45…65Hz
I: 0,83A
P: 20 W
4.3519.20.xxx U: 24V AC/DC, 45…65Hz
I: 0,42A
P: 10 W
4.3519.40.xx U: 24V AC/DC, 45…65Hz
I: 2,5A
P: 60 W
Operating voltage heating
-40°C...70°C
Survival speed
maximally 80 m /s, 30 minutes
Connection See
model
Dimensions
See dimensional drawing
Montage
For ex. onto mast tube with receptacle thread Pg 21 or boring Ø 29 mm
Protection IP
55
Weight
0,40 – 0,75 kg depending on model
Material
Housing
Cup star
Bottom
Aluminium (AlMgSi1)
Synthetic, with fibre glass (PC-GF10)
Synthetic (POM H2320)
Содержание 4.3519 Series