![Thies CLIMA 4.3515.5 Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/thies-clima/4-3515-5-series/4-3515-5-series_instructions-for-use-manual_1106925005.webp)
transmitter should be set up a height where local obstacles do not influence the measured values to
any significant extent (approx. 6 - 10 m above the obstacle).
The wind transmitter should be set up in the centre of flat roofs and not on the roof side in order to
avoid bias in the direction (privileged directions).
5 Installation
Remark:
When using fastening adapters (angle, traverses, brackets etc.) please take a
possible effect by turbulences into consideration.
Attention:
Storing, mounting and operation under weather conditions is
permissible only in vertical position, as otherwise water can get into
the instrument.
5.1 Mechanical Mounting
Install wind transmitter and
mounting angle by means of
the pictured screws.
Afterwards, please mount both
on a suited mast or instrument
carrier.
The cable is to be fastened
tightly on mast or instrument
carrier traverse by means of
brackets, cable connectors or
similar mounting material.
5.2 Electrical Mounting
The electrical connection is carried out acc. to the connection diagram (chapter
5 - 10