6 Connecting
Diagram
Note:
The small
wind transmitter w/o
heating is dispensed
with 3 + 4
7 Maintenance
After proper mounting the instruments works maintenance-free.
Heavy pollution can clog up the slit between the rotating and the stationary parts of the wind
transmitter. This slit must be kept clean
8 Technical
Data
4.3515.50.000
4.3515.50.100
4.3515.60.115
4.3515.50.109
4.3515.51.000
4.3515.51.100
4.3515.51.110
4.3515.61.100
Measuring range
0.9...40 m/s
Electrical output
100Hz @ 40m/s (typ. 2,5Hz / ms
-1
)
Resolution
0.4 m wind run
Accuracy
± 0.5 m/s or ± 5% of measuring value
Measuring system
1 x Reed-contact, 2 x magnet
Contact Reed-contact
Contact load (Reed-contact)
10 VA, max. 42 V DC, max. 0.4 A
Load
max. 60 m/s for a short time
Heating (PTC, max.80°C)
24 V AC / DC (80 °C)
12 V AC / DC
---------------
Switch-on current
max. 1 A (3 sec.)
max. 4 A (3 sec.)
---------------
Ambient temperature
- 25 °C ... + 60 °C (with ice-free condition)
Material plastic
ABS
Connection
See models available
Dimensions
See dimensional diagram
Weight 0.3
kg
Kabel
1 2
3 4
1 revolution
= 2 pulses
reed contact
heating
6 - 10
021150/02/12
Содержание 4.3515.5 Series