© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021814/03/21
Phone +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] · www.thiesclima.com
Page 76 of 86
Position
Length Sample
Description
67
1
;
Separation marks (’;’)
68
4
xxxx
Acceleration vibration measurement, y-axis (unit: mg)
xxxx: acceleration; Resolution: 1mg
72
1
;
Separation marks (’;’)
73
5
xxx.x
Frequency vibration measurement, z-axis (unit: Hz)
xxx.x: frequency; Resolution: 0.1Hz
78
1
;
Separation marks (’;’)
79
4
xxxx
Acceleration vibration measurement, z-axis (unit: mg)
xxxx: acceleration; Resolution: 1mg
83
1
;
Separation marks (’;’)
84
8
abcdefgh 32Bit Sensor status hexadecimal representation
a: high nibble im high byte in HEX (Bit 31 … 28)
b: low nibble im high byte in HEX (Bit 27 … 24)
c: high nibble im byte 2 in HEX (Bit 23 … 20)
d: low nibble im byte 2 in HEX (Bit 19 … 16)
e: high nibble im byte 3 in HEX (Bit 15 … 12)
f: low nibble im byte 3 in HEX (Bit 11 … 8)
g: high nibble im low byte in HEX (Bit 7 … 4)
h: low nibble im low byte in HEX (Bit 3 … 0)
92
1
*
Separation marks (’*’)
93
2
xy
Exclusive or linked checksum in hexadecimal notation
x: high nibble check sum in HEX
y: low nibble check sum in HEX
95
1
ETX
End of text
96
1
CR
Carriage Return
97
1
LF
Line feed
Table 14: Value-Telegram 6
Pressure and acceleration sensors are thermally coupled.
12.6 Measured Value Memory Telegram
The measuring values of the wind velocity (without compensation) acquired by means of
standard characteristic curve) are buffered in a ring memory comprising 16 values. The time
distance between the measured values is defined by parameter SR. The wind transmitter re-
sponds with the measured value memory telegram to the command “00TR30\r”. The table
below shows the telegram structure:
Position
Length Example
Description
1
1
STX
Start character (start of text)
2
5
xxxxx
Time since the last query in (unit: ms)
7
1
;
Separation character (’;’)
8
5
xxx.x
Most recent measured value (0); unit: m/s; resolution: 0.1m/s
13
1
;
Separation character (’;’)
14
5
xxx.x
Measured value (1); unit: m/s; resolution: 0.1m/s
19
1
;
Separation character (’;’)
20
5
xxx.x
Measured value (2); unit: m/s; resolution: 0.1m/s
25
1
;
Separation character (’;’)
26
5
xxx.x
Measured value (3); unit: m/s; resolution: 0.1m/s
31
1
;
Separation character (’;’)