1 Models 

available 

Order - No. 

Meas. range 

Output 

Frequency 

Supply Heating 

4.3351.00.000 

0.3...75 m/s 

1082 Hz @ 50 m/s  3.3…48 V DC  24V AC/DC, 25 W 

4.3351.10.000 

0.3...75 m/s 

1082 Hz @ 50 m/s  3.3…48 V DC 

w/o heating 

 

The following parts are included in delivery: 
1 Instrument 
1 Terminal plug 
1 Instruction for Use 

 

 

2 Application 

The wind transmitter is designed for the acquisition of the horizontal component of the wind speed 
in the field of meteorology and environmental measuring technology, evaluation of location, and 
measurement of capacity characteristics of wind power systems. 
Special characters are defined and optimised, dynamic behaviour also at high turbulence intensity, 
minimal over-speeding, and a low starting values. 
The measuring value is available as digital signal at the output. It can be transmitted to display in-
struments, recording instruments, data loggers as well as to process control systems. For winter 
operation the instrument is optional equipped with an electronically regulated heating, which guar-
antees a smooth running of the ball bearings, and prevents the shaft and slot from icing-up. 

 

3  Construction and Mode of Operation 

A low-inertia cup star with 3 cups, made of carbon-fibre-reinforced plastic, is set into rotation by the 
wind. The rotation is scanned opto-electronically, and is converted into a square wave signal. The 
frequency of this signal is proportional to the number or rotations. Depending on the supply voltage, 
the output signal ranges between  maximal output voltage and ground or a potential (life-zero

*

), 

lifted by approx. 1.2 V. The supply of the electronics can be done by DC-voltage of 3.3 V up to 48 V 
at a very low current consumption. An AC- or DC-voltage of 24 V is intended for the separate sup-
ply of the optional heating. In all probability, the heating guarantees a trouble-free function of the 
Wind Transmitter First Class even under extreme meteorological icing-conditions.  

The outer parts of the instrument are made of corrosion-resistant anodised aluminium. Highly effec-
tive labyrinth gaskets and O-rings protect the sensitive parts inside the instrument against humidity 
and dust. The instrument is mounted onto a mast tube; the electrical plug-connection is located in 
the transmitter shaft. 

                                                 

*

 

Useable at a supply voltage > 5 V DC 

 

Содержание 4.3351.00.000

Страница 1: ...4 3351 10 000 Instruction for Use 021519 01 09 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com...

Страница 2: ...ns The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device p...

Страница 3: ...2 Electrical Mounting 6 5 2 1 Cable 6 5 2 1 1 Cable Recommendation 6 5 2 2 Cable Shield 6 5 2 2 1 Connecting Recommendation for the Cable Shield 7 5 2 3 Plug and Cable Mounting 8 5 3 Connecting Diagra...

Страница 4: ...oth running of the ball bearings and prevents the shaft and slot from icing up 3 Construction and Mode of Operation A low inertia cup star with 3 cups made of carbon fibre reinforced plastic is set in...

Страница 5: ...fulfilled the measuring instrument should be installed at a height at where the measurement values are not influenced by any local obstacles In any case the measuring instruments should be in stalled...

Страница 6: ...e inner diameter of the instrument carrier should be 20 mm based on plug and cable feed through 5 2 Electrical Mounting 5 2 1 Cable Solder a shielded cable with diameter 7 8 mm and a core cross sectio...

Страница 7: ...ng protection rod on the mast in isolated condition and ground lightning protection rod Alternatively Install separate lightning protection rod beside the measurement mast 3 Metallic measurement mast...

Страница 8: ...d back ward on the cable sheath 3 Soldering wire to the insert positioning shield in cable clamp 4 Screwing on cable clamp 5 Assembling remaining parts acc to upper plan 6 Tightening pull relief of ca...

Страница 9: ...red joint of the counter plug 1 2 3 4 5 6 7 8 Order No 4 3351 10 without heating Pin 7 u 8 are not connected Pin 5 u 6 Do not connect 9 16 021519 01 09 Pin Name Function 1 SIG Signal rectangle 2 GND G...

Страница 10: ...the cleaning of the device should use a damp cloth without chemical cleaning agents are used Certain symptoms of wear and tear can appear on the ball bearings after years of use These symptoms are exp...

Страница 11: ...m s Starting velocity 0 3 m s Resolution 0 05 m wind run Distance constant 3 m acc to ASTM D 5096 96 3 m acc to ISO 17713 1 Turbulent flow Deviation v turbulent compared with stationary horizontal fl...

Страница 12: ...ed cable in the shaft see connecting diagram Mounting Mounting on mast R 1 for ex DIN 2441 1 with separate adaptor option Dimensions See dimension diagram Weight approx 0 5 kg Protection IP 55 DIN 400...

Страница 13: ...to mast 1 m Mast clamp 40 80 mm Tube diameter 34 mm Material Aluminum Lightning rod For mounting the a m trav erse or hanger 4 3100 98 000 Dimension 12 mm 500 mm long 1050 mm high Material Aluminum A...

Страница 14: ...HE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equip ment designed for use within certain voltage limits 552 200...

Страница 15: ...15 16 021519 01 09...

Страница 16: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 16 16 02151...

Отзывы: