Thies CLIMA 4.3120.22 Series Скачать руководство пользователя страница 2

 

Safety Instructions

• 

Before operating with or at the device/product, read through the operating instructions. 
This manual contains instructions which should be followed on mounting, start-up, and operation.  
A non-observance might cause: 
 

 

- failure of important functions 

 

 

- Endangering of persons by electrical or mechanical effect 

 

 

- Damage to objects 

• 

Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician 
who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. 

• 

Repairs and maintenance may only be carried out by trained staff or 

Adolf Thies GmbH & Co. KG

. Only 

components and spare parts supplied and/or recommended by 

Adolf Thies GmbH & Co. KG

 should be used for 

repairs.  

• 

Electrical devices/products must be mounted and wired only in voltage-free state. 

• 

Adolf Thies GmbH & Co KG

 guarantees proper functioning of the device/products provided that no 

modifications have been made to the mechanics, electronics or software, and that the following points are 
observed: 

• 

All information, warnings and instructions for use included in these operating instructions must be taken into 
account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring 
system / device / product.  

• 

The device / product is designed for a specific application as described in these operating instructions. 

• 

The device / product should be operated with the accessories and consumables supplied and/or recommended 
by 

Adolf Thies GmbH & Co KG

 . 

• 

Recommendation: As it is possible that each measuring system / device / product under certain conditions, and 
in rare cases, may also output erroneous measuring values, it is recommended using redundant systems with 
plausibility checks with 

security-relevant applications

Environment 

• 

As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the 
objectives of environmental protection and is therefore willing to take back all supplied products 
governed by the provisions of "

ElektroG

(

German Electrical and Electronic Equipment Act) 

and to perform environmentally compatible disposal and recycling. We are prepared to take 
back all Thies products concerned free of charge if returned to Thies by our customers 
carriage-paid. 

 

• 

Make sure you retain packaging for storage or transport of products. Should packaging 
however no longer be required, arrange for recycling as the packaging materials are designed 
to be recycled. 

 

Documentation 

• 

©  Copyright 

Adolf Thies GmbH & Co KG

, Göttingen / Germany 

• 

Although this operating instruction has been drawn up with due care, 

Adolf Thies GmbH & Co KG

 can accept 

no liability whatsoever for any technical and typographical errors or omissions in this document that might 
remain. 

• 

We can accept no liability whatsoever for any losses arising from the information contained in this document. 

• 

Subject to modification in terms of content. 

• 

The device / product should not be passed on without the/these operating instructions. 

 

 

2 - 12 

021262/11/07

 

 

Содержание 4.3120.22 Series

Страница 1: ...TA Instruction for Use 021262 11 07 Wind Direction Transmitter with potentiometer output 4 3120 22 xxx ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone...

Страница 2: ...ons The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device...

Страница 3: ...7 8 Technical Data 8 9 Dimensions 9 10 EC Declaration of Conformity 10 Figure Figure 1 Dimension 4 3120 22 0xx 9 Figure 2 Dimension 4 3120 22 712 9 1 Models Order No Meas range WD Electrical Output Mo...

Страница 4: ...3 Construction and Mode of Operation The housing and wind vane are made of aluminum die the surfaces are anodized Labyrinth seals and o rings protect the sensitive internal parts from precipitation Th...

Страница 5: ...er No 4 3100 99 000 is recommended if the instrument is to be used in areas with considerable lightning activity 5 1 Mounting the wind vane Unscrew the cap nut SW 8 from the case of the Wind Direction...

Страница 6: ...mitter is the roll axis of the ship whereat 0 is related to the ship bow Rotate the case markings north marking on the shaft and on the protective cap until they are aligned Take a bearing on ship bow...

Страница 7: ...ion of max 1 mA When using power supply units temporary current peaks with the power control might lead to damages Therefore an additional protective resistance Is strongly recommended Order no 4 3120...

Страница 8: ...st guarantee a current limiting to max 1 mA short cut at the North point max 24 V 1 5 W max 24 V 1 5 W The supply must guarantee a current limiting to max 1 mA short cut at the North point Heating 24...

Страница 9: ...9 Dimensions 125 425 415 70 50 36 50 Figure 1 Dimension 4 3120 22 0xx 60 300 280 70 50 36 50 Figure 2 Dimension 4 3120 22 712 9 12 021262 11 07...

Страница 10: ...States relating to electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 March 2004 on the interop...

Страница 11: ...11 12 021262 11 07...

Страница 12: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 12 12 02126...

Отзывы: