So, to do it, the input and static bypass switches will have to 
be turned «Off».

Put warnings of danger and/or emergency switches if the safety 
Standards require it in your particular installation.

Ŗ

It is possible that the UPS supplies output voltage 
through the manual bypass to those equipments that 

incorporate it either standard or optional, so it will have to be 
considered as regards to safety. If it were necessary to break 
the output supply of the equipment in this situation, deactivate 
the outgoing distribution protection or in case of lack of it the 
general protection of the distribution panel that feeds the UPS. 

Ŗ

All power supply electrical cables have to be fixed to the 
equipments and loads, interfaces, etc..., to unmovable parts 
and in the way to avoid treads, trips on them or fortuitous 
pulls.

Ŗ

CHASSIS or RACK mounted equipments are destined to be in-
stalled in a predetermined set to be done by professionals.

 

ˆ

The installation has to be designed and executed by qual-
ified personnel, who will be the responsible to apply the 
safety and EMC regulations and standards that controls 
the particular installations where the product is destined.

 

ˆ

The equipments assembled in CHASSIS do not have 
enclosure protection, even the power blocks are unpro-
tected.

 

ˆ

Some RACK mounted equipments do not have the power 
blocks protected.

Ŗ

Never manipulate the equipment with wet hands.

1.2.3.2.  To keep in mind.

Ŗ

Do not try to dismantle or change any part of the 
equipment, if this action is not contemplated in this 

document. Manipulation inside the UPS due to any modifica-
tion, reparation or any other cause, can make an electrical 
discharge of high voltage and it is restricted to qualified staff 
only. Do not open the equipment.

A part from the implicit stated risks, any action that make the 
modification, internal or external of the equipment or just only 
the simple intervention inside of itself, which is not stated in 
this document, it can expire the warranty

Ŗ

If it is observed that the UPS exhausts smoke or toxic gas, 
shutdown it immediately and disconnect it from the power 
supply. This kind of fault can cause fire or electrical dis-
charge. Contact with our 

(

S.T.S.

)

.

Ŗ

In case of an accidental equipment dropping or if the enclo-
sure is damaged, do not start it up under any concept. This 
kind of fault can cause fire or electrical discharge. Contact 
with our 

(

S.T.S.

)

.

Ŗ

Do not cut, manipulate the electrical cables, do not put heavy 
objects over them too. Any of these actions could cause a 
short-circuit and make a fire or electrical discharge.

Check that the electrical cables of connection, plugs and out-
lets are in good conditions.

Ŗ

When moving an equipment from a cold place to a warm en-
vironment and vice versa, it can cause condensation (small 
water drops) in the external and internal surfaces. Before in-
stalling a moved equipment from another place or even pack-
aged, the equipment will be left for a minimum time of two 
hours in the new location before making any action, with the 
purpose of adapting it to the new environmental conditions 
and avoid the possible condensations.

The UPS has to be completely dry before starting any instal-
lation task.

Ŗ

Do not store, install or expose the equipment in corrosive, 
wets, dusty inflammable or explosive environments and 
never outdoors.

Ŗ

Avoid to locate, install or store the equipment in a place with 
direct sunlight or high temperatures. Batteries could be dam-
aged.

In the exceptional case and long exposition to intense heat, 
batteries can cause filtrations, overheating or explosions, 
which can cause fires, burn or other injuries. High tempera-
tures can also make deformation in the plastic enclosure.

Ŗ

The location will be spacious, airy, away from heat sources 
and easy access.

Ŗ

Do not obstruct the cooling grids by entering objects through 
themselves or other orifices.

Ŗ

 Leave as minimum space of 25 cm in the equipment pe-
ripheral.

Ŗ

Do not put materials over the equipment or parts that obstruct 
the correct visualization of the synoptic.

Ŗ

Be careful to not wet it, because it is not waterproof. Do not 
allow entering any kind of liquids in. If accidentally the outside 
of the machine comes into contact with liquids or salt air, dry 
it with a soft and absorbent cloth. 

Ŗ

To  clean  the  equipment,  wipe  over  a  damp  cloth  and  then 
dry it. Avoid sprinkling or spillage that could enter through the 
slots or cooling grids, which may cause fire or electric shock.

Do not clean the equipments with products that could have 
alcohol, benzene, solvent or other inflammable substances, 
or they are abrasive, corrosive, liquids or detergent.

Ŗ

Be careful to not lift heavy loads without help, according to 
the following recommendations:

 

ˆ

d

, < 18 kg.

 

ˆ

dd

, 18 - 32 kg.

 

ˆ

ddd

, 32 - 55 kg.

 

ˆ

, > 55 kg.

Ŗ

UPSs are electronic equipments, so they will be treated as 
they are:

 

ˆ

Avoid shocks.

 

ˆ

Avoid jolting or bouncing of the UPS, like those produced 
by moving the equipment on a hand truck and move on 
an uneven or wavy surface.

Ŗ

UPS transport will be done packaged inside its original pack-
aging in order to prevent it from shock and impact and by 
means of the suitable type of packaging (carton box, pallet 
packaging, ...) and appropriate to its weight.

Ŗ

Although the physical location of the elements can differ from 
the illustrations in this manual in some cases, the correct la-
belling correct the possible doubts and makes easy its com-
prehension.

1.2.3.3.  Safety warning regarding batteries.

Ŗ

The manipulation and connection of the batteries 
shall be done and supervised by personnel with 

battery knowledge only.

Before doing any action, disconnect the batteries. Check that 
no current is present and there is not dangerous voltage in 
the DC BUS (capacitors) or in the endpoint of the battery set 
terminals.

Battery circuit is not isolated from input voltage. Dangerous 
voltages can be found between the terminals of the battery 
set and the earth. Check that there is not any voltage at the 
input before take any action over them.

USER MANUAL

Thiele KG • V

orderer W

einberg 26 • D-71522 Backnang • T

el.:(07191)3560-0 • Fax.:(07191)3560-19 • info@thiele-electroni

c.de • www

.thiele-electronic.de

Thiele KG • V

orderer W

einberg 26 • D-71522 Backnang • T

el.:(07191)3560-0 • Fax.:(07191)3560-19 • info@thiele-electroni

c.de • www

.thiele-electronic.de

Vorderer Weinberg 26

 • D-71522 Backnang • 

Tel.:+49 (0)7191 3560-0 (Fax.:-19)

Содержание SPS.1000.ADV RT

Страница 1: ...VANCE RT series UNINTERRUPTIBLE POWER SUPPLY USER S MANUAL Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 07191 3560 0 Fax 07191 3560 19 info thiele electronic de www thiele electronic de Thiele...

Страница 2: ...x 07191 3560 19 info thiele electronic de www thiele electronic de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 07191 3560 0 Fax 07191 3560 19 info thiele electronic de www thiele electronic de...

Страница 3: ...minals in UPSs 1kVA Emergency Power Off 4 3 6 Communication port 4 3 6 1 RS232 and USB interface 4 3 6 2 Smart slot 4 3 6 3 AS400 Interface with DB9 output option 4 3 6 4 Protection against transient...

Страница 4: ...ntents the basic in structions and features for the equipment safety To not respect these indications can create material damages on the own equip ment installation or loads Notes of information symbo...

Страница 5: ...ne of them It is essential that the cables that supplies the loads have the earth connection cable The protection earth must be connected to the frame or metallic chassis of any electrical equipment i...

Страница 6: ...l conditions and avoid the possible condensations The UPS has to be completely dry before starting any instal lation task Do not store install or expose the equipment in corrosive wets dusty inflammab...

Страница 7: ...ubber gloves and shoes Use tools with insulated handles Take off watches rings or other metal objects Do not place metal tools or objects over the batteries Never manipulate with your hands or through...

Страница 8: ...safety requirements for UPS s used in ac cessible areas by end users EN IEC 60950 1 IT equipments Safety Part 1 General re quirements EN IEC 62040 2 Uninterruptible power supply UPS Part 2 EMC requir...

Страница 9: ...with LCD Plastic beauty front Front view battery module for ADVANCE RT Fig 1 Front view models from 0 7 to 10 kVA and battery modules for extended back up times 3 1 2 Legend corresponding to the equip...

Страница 10: ...ets LS2 Input connector for modem ADSL Fax line RS232 COM port Standard 3000 VA and B1 model IEC outlets LS1 USB COM port IEC inlet for AC power supply Earth connection for battery module Output conne...

Страница 11: ...ule i Note relative to the batteries B0 and B1 acronyms stated the nomenclature related to batteries B0 The equipment is supplied without batteries and without accessories for them screws and electric...

Страница 12: ...han 1000 VA it is possible to increase the standard back up time of the equipments by connecting additional modules and or to optimise the recharging time of the accumula tors by fitting chargers with...

Страница 13: ...The available SNMP option for SPS ADVANCE RT series is a card to be inserted into the slot that the UPS has in its rear side The connection of the UPS with the SNMP is internal meanwhile the connecti...

Страница 14: ...act has to be fitted in residual current device at the output of each transformer because due to its specification of isolation it will prevent the triggering of the protections fitted in the primary...

Страница 15: ...s Cut the strips of cardboard enclosure Remove the accessories cables supports Remove the equipment or battery module from the pack aging keeping in mind that the it is needed the help of a second per...

Страница 16: ...se way as its removing see section 4 2 4 1 4 2 4 3 Vertical assembling tower type Rotate the control panel according to section 4 2 4 2 Take the 4 plastic pieces A with angle shape supplied with the e...

Страница 17: ...eak the needed trims to pass the connection bus Put the beautiful front cover back of the equipment and battery module as it is stated in section 4 2 4 1 4 2 4 5 19 rack cabinet assembling All models...

Страница 18: ...of them is 2 units Proceed as follows Fix both adaptor angles A to the equipment and to the battery module as rack on their side by means of the supplied screws C B F G J K K H Fig 9 Model in rack mou...

Страница 19: ...to the terminal before connecting the power supply to the input power block All the equipments have female IEC outlets in greater or lesser numbers depending on the power rate of the equipment Models...

Страница 20: ...y of the two cables that goes from the button to the UPS were cut damaged On the other hand this failure would be immediately detected in the normally open EPO type with the inconvenience of the sudde...

Страница 21: ...nPower is a UPS monitoring software which makes a user friendly interface of monitoring and management This software supplies an auto Shutdown for a system based on several PCs in case of an electrica...

Страница 22: ...d that the equipment becomes blocked under the worst conditions It is better to not connect the loads of this kind due to the high quantity of energy resources that take from the UPS USER MANUAL Thiel...

Страница 23: ...S start up with mains present For the daily start up of the equipment press over the start up key for more than 3 seconds the acoustic alarm will beep for 1 sec and the UPS will start up Fan will be s...

Страница 24: ...Blue OPVH Fault Battery mode with output voltage too high Red OPVL Fault Output voltage is too low Red OPST Fault Short circuit at the output Red OVLD Warning Overload Red BATH Warning Battery voltage...

Страница 25: ...e 001 Wide range 002 Gen set EBM External battery module 0 9 it is the quantity of battery modules TEST Auto test 000 Deactive 001 Active AR Automatic restart 000 Deactive 001 Active GF Green mode 000...

Страница 26: ...e second to enter into the element to set 4 Select the configuration value Press the key to select the quantity of battery mod ules available for the UPS 5 Confirm the configuration Press the key for...

Страница 27: ...he batteries so there are hazardous voltages in side Therefore before doing any reparation or maintenance task the internal battery fuses and or the interlink connections be tween them and the UPS hav...

Страница 28: ...dequate testing tentative of repairing or not authorized modification or any other cause beyond the foreseen use or by accident fire lightnings or other dangers Neither it will cover in any case compe...

Страница 29: ...al or total way with the purpose to be adapted to the customer s need Consult our Website to have more information 7 5 Technical service network Coverage both national and international from our Servi...

Страница 30: ...Voltage accuracy battery mode 5 Voltage THD linear load 10 3 Voltage THD non linear load 12 6 Frequency With mains present synchronised to nominal of the input 45 55 55 65 Hz Free running battery mode...

Страница 31: ...example the one supplied by the battery it is con tinuous any current that always maintain the polarity DSP It is the acronym of Digital Signal Processor A DSP is a system based on a processor or mic...

Страница 32: ...irect cur rent This is done by rectifier diodes which can be solid state semiconductors vacuum or gassy valves as the mercury vapour Depending on the features of the alternating current power supply u...

Отзывы: