background image

Asian Electron Co., Ltd.

PSW1500W / PSW2000W Series

Pure Sine Wave Inverter

Instruction Manual

Y O U R   C O N N E C T I O N   TO   S A F E T Y

Thiele KG 

• V
orderer W

einberg 26 • D-71522 Backnang • T

el.: +49 (0)7191 3560-0 

• Fax.: +49 (0)7191 3560-19 

[email protected] 

• www

.thiele-kg.de

Thiele KG 

• V

orderer W

einberg 26 • D-71522 Backnang • T

el.: +49 (0)7191 3560-0 

• Fax.: +49 (0)7191 3560-19 

[email protected] 

• www

.thiele-kg.de

YOUR CONNECTION TO SAFETY

klick to

www

u-s-v

YOUR CONNECTION TO SAFETY

klick to

www

ACDC-DCDC

YOUR CONNECTION TO SAFETY

klick to

www

SYSTEME

YOUR CONNECTION TO SAFETY

klick to

www

CONTACT

YOUR CONNECTION TO SAFETY

klick to

www

CALLBACK

Содержание Asian Electron PSW1500W Series

Страница 1: ...0 19 info thiele kg de www thiele kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg de www thiele kg de YOUR CONNECTION TO SAFETY klick to...

Страница 2: ...tions 17 6 2 Precautions when working with batteries 17 7 Appendices A 7 1 Dip switch 18 7 2 Tune VR 18 8 Appendices B 8 1 Powering saving mode 18 YOUR CONNECTION TO SAFETY Thiele KG Vorderer Weinberg...

Страница 3: ...ncandescent lights shavers sewing machines 1 1 4 Kitchen appliances microwave ovens refrigerators and freezers coffee makers blenders ice markers toasters 1 1 5 Industrial equipment metal halide lamp...

Страница 4: ...Polarity fuse Input Undervoltage Input Overvoltage Over Temperature Digital Display OVP UVP OTP OLP VAC AMP WATT VDC TEMP Hz Safety EN60950 1 EMC FCC Class B EN55022 2010 AC 2011 Class B EN55024 2010...

Страница 5: ...40A 0 40A 0 20A Stand by Current Draw 1 5W Power Saving Mode Output Waveform R Load Pure Sine Wave 3 THD Protection Overload Short Circuit Reverse Polarity Fuse Input Undervoltage Input Overvoltage Ov...

Страница 6: ...thiele kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg de www thiele kg de YOUR CONNECTION TO SAFETY klick to www u s v YOUR CONNECTION...

Страница 7: ...t will display various status on the function screen such as VAC Amp watts and so on When malfunction is occurred its display will be flashed on the screen YOUR CONNECTION TO SAFETY Thiele KG Vorderer...

Страница 8: ...and may damage inverter permanently YOUR CONNECTION TO SAFETY Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg de www thiele kg de Thiele KG V...

Страница 9: ...inberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg de www thiele kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info...

Страница 10: ...engine compartments 2 3 4 Ventilated Allow at least 3 inch of clearance around the inverter for airflow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed 2 3 5 Dust...

Страница 11: ...output power source CAUTION Reverse polarity connection will blow a fuse in inverter and may permanently damage the inverter Damage caused by reversing polarity connection is not covered by our warra...

Страница 12: ...ction neutral of the inverter s AC output to input safety ground is not present so that the utility neutral is only connected to ground at your breaker panel as required 2 5 1 2 230V Models There is n...

Страница 13: ...drop WARNING The installation of a fuse must be on positive cable Failure to place a fuse on cables running between the inverter and battery may cause damage to the inverter and will void warranty In...

Страница 14: ...m the power inverter turn them on separately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once YOU...

Страница 15: ...W220200 YK PSW220200E 275VDC 270VDC 185VDC 180VDC 2 7 2 Output Voltage indicator LED displays light on VAC as show as output voltage value 2 7 3 Output Current indicator LED displays light on AMP as s...

Страница 16: ...r has shut itself down because its temperature has become overheated The power inverter may overheat because it has been operated at power levels above its rating or because it has been installed in a...

Страница 17: ...hooting Guide WARNING Do not open or disassemble the inverter Attempting to service the unit yourself may result in a risk of electrical shock or fire Problem and Symptom Possible Cause Solution Low o...

Страница 18: ...that existing wiring is in good electrical condition and that wire size is not undersized Do not operate the inverter with damaged or substandard wiring 6 2 Precautions When Working with Batteries 6 2...

Страница 19: ...watts the inverter shuts down the output power Only essential systems are kept alive to reduce power consumption from the batteries to a very low value of only about 1 5 watts As soon as a load is swi...

Отзывы: