Fixing
Fixing screw positions are located on each side of oven opening and are accessed by
opening the door. Screw into place using a flange head No 6 woodscrew
Connection
A ¼ BSP female connection is provided for gas inlet, on the rear of the appliance. It is
recommended that the appliance be connected by copper tubing, a rubber or hose
connection must not be used. After connection the appliance must be tested for
soundness.
This appliance is suitable for use on –
Universal LPG Only 2.75 Kpa
.
It is important that the regulator should be set to the correct pressure for the type of gas
being used. Excessive pressure must not be permitted.
If the flame on either burner has a tendency to lift, it is probable that the line pressure is
too great. Should there be excessive yellow tips (resulting in soot) then it is probable that
the line pressure is too low and, in either case, the burners should not be used until the
line pressure has been checked.
This appliance is fitted with the following injectors:-
GRILL
0.62mm 5.3 MJ/h
OVEN
0.62mm 5.3 MJ/h
The burners on this appliance have fixed aeration and no adjustment is necessary.
After installation the appliance MUST be tested for soundness, when satisfied with
the appliance, please instruct the user on the correct method of operation. If the
appliance fails to operate correctly after all checks have been made, refer to the
authorised service provider in your area.
WARNING
When installing DO NOT lift appliance using the door handles.
INSTALLATION
IMPORTANT
•
This appliance MUST be earthed
•
A constant 12V supply is necessary at all times to ensure the cooling
system operates correctly.
•
Test ALL burners on high and low flame for flame stability.
•
The gas supply input pressure MUST not rise or fall significantly from
nominal when ALL appliances connected to the supply are operated
simultaneously. If NOT installed to the manufacturers instructions detailed
herein, we the manufacturer can not be held responsible for any problems
that occur, or poor performance that is perceived/witnessed.